A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visual Outcomes of a Second-Generation, Enhanced UV Protected Light Adjustable Lens in Cataract Patients with Previous LASIK and/or PRK. | LitMetric

Purpose: To report on the visual outcomes of the second-generation (ActivShield) Light Adjustable Lens (LAL) used in cataract surgery for patients with a history of laser refractive surgery (LASIK and/or photorefractive keratectomy [PRK]) using a co-managed, open-access methodology.

Patients And Methods: This retrospective case series of consecutive patients with history of laser refractive surgery implanted with the second-generation LAL with an emmetropic target were included in the study. Following surgery, all patients received their ultraviolet (UV) light treatments at a separate open-access facility through a co-managed arrangement. Uncorrected distance visual acuity (UDVA), spherical equivalent (SE), and residual cylinder for eyes with an emmetropic refractive target were the primary outcome measures as documented at the patient's final, stable, refractive postoperative exam.

Results: Thirty-three patients (34 eyes) with a history of laser refractive surgery were included in the study and implanted with the second-generation LAL with a postoperative emmetropic refractive target. Twenty-eight (82.4%) saw 20/20 or better and 9 (26.5%) saw 20/15 or better. The mean SE was 0.01 ± 0.31 D and 33 (97.1%) were within ±0.50 D SE of plano. The mean residual cylinder was -0.28 ± 0.32 D and 30 (88.2%) were within ±0.50 D.

Conclusion: Use of the second-generation LAL was efficacious in cataract surgical patients with a history of LASIK and/or PRK using a co-managed, open-access methodology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10637228PMC
http://dx.doi.org/10.2147/OPTH.S432457DOI Listing

Publication Analysis

Top Keywords

lasik and/or
12
patients history
12
history laser
12
laser refractive
12
refractive surgery
12
second-generation lal
12
visual outcomes
8
outcomes second-generation
8
light adjustable
8
adjustable lens
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!