A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Lumen segmentation using a Mask R-CNN in carotid arteries with stenotic atherosclerotic plaque. | LitMetric

In patients at high risk for ischemic stroke, clinical carotid ultrasound is often used to grade stenosis, determine plaque burden and assess stroke risk. Analysis currently requires a trained sonographer to manually identify vessel and plaque regions, which is time and labor intensive. We present a method for automatically determining bounding boxes and lumen segmentation using a Mask R-CNN network trained on sonographer assisted ground-truth carotid lumen segmentations. Automatic lumen segmentation also lays the groundwork for developing methods for accurate plaque segmentation, and wall thickness measurements in cases with no plaque. Different training schemes are used to identify the Mask R-CNN model with the highest accuracy. Utilizing a single-channel B-mode training input, our model produces a mean bounding box intersection over union (IoU) of 0.81 and a mean lumen segmentation IoU of 0.75. However, we encountered errors in prediction when the jugular vein is the most prominently visualized vessel in the B-mode image. This was due to the fact that our dataset has limited instances of B-mode images with both the jugular vein and carotid artery where the vein is dominantly visualized. Additional training datasets are anticipated to mitigate this issue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10841729PMC
http://dx.doi.org/10.1016/j.ultras.2023.107193DOI Listing

Publication Analysis

Top Keywords

lumen segmentation
16
mask r-cnn
12
segmentation mask
8
trained sonographer
8
jugular vein
8
lumen
5
plaque
5
carotid
4
r-cnn carotid
4
carotid arteries
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!