A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of Renal Access Angle and Speed of Nephroscope Retrieval Movements on the Vortex Effect. | LitMetric

Objective: To analyze the influence of different renal access angles (AAs) and nephroscope retrieval speeds on the efficacy of the vortex effect (VE) in mini-percutaneous nephrolithotomy (mini-PCNL). This study aimed to understand the poorly understood physical components of the VE.

Materials And Methods: A Pexiglas™ (KUS®) model was built based on the dimensions of a 15/16 F mini-PCNL set (Karl Storz). The flow rate was continuous via an automatic pump and calibrated to achieve hydrodynamic equivalence to the real equipment. One experiment consisted of manually retrieving all 30 stone phantoms (3 mm diameter) utilizing only the VE. Cumulative time to retrieve all stones was measured. An accelerometer recorded instant speeds of the nephroscope every 0.08 seconds (s), and 3 experiments were performed at each angle (0°, 45°, and 90°). A logistic regression model was built utilizing maximum speeds and access angles to predict the effectiveness of the VE.

Results: Mean cumulative time for complete stone retrieval was 28.1 seconds at 0° vs 116.5 seconds at 45° vs 101.4 seconds at 90° (P < .01). We noted significantly higher speeds at 0° compared to 45° and 90° (P < .01); however, differences in average and maximum speed between 45° and 90° were not statistically significant (P = .21 and P = .25, respectively). The regression model demonstrated a negative association between increasing maximum speed and VE's effectiveness (OR 0.547, CI 95% 0.350-0.855, P < .01). When controlling for maximum speed, the 0° angle had significantly higher chances of achieving at least a partially effective VE.

Conclusion: Increasing the renal access angle or nephroscope extraction speed negatively impacts the effectiveness of the VE. This significantly increased procedure time in the laboratory model, suggesting that the VE is less effective at higher sheath angles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2023.10.030DOI Listing

Publication Analysis

Top Keywords

renal access
8
nephroscope retrieval
8
access angles
8
model built
8
cumulative time
8
impact renal
4
access angle
4
angle speed
4
speed nephroscope
4
retrieval movements
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!