Purpose: To evaluate the impact of residual astigmatism on the optical and visual performance of an enhanced-monofocal isofocal intraocular lens (EM Isopure, BVI medical, Belgium) compared to a monofocal one (Micropure, BVI medical, Belgium).
Methods: Laboratory investigation and prospective, comparative and randomized clinical study. Optical quality was assessed on an optical bench for 2.0, 3.0, and 4.5 mm pupils. The effect of residual astigmatism was investigated from through-focus images recorded with increasing amounts of regular positive astigmatism induced with a deformable mirror. To evaluate the impact of residual astigmatism, 28 eyes of 28 patients were randomly assigned to either group. Residual astigmatism was induced with positive and negative cylinder lenses at 90 and 180°. Visual acuity (VA) was measured at each step.
Results: The optical performance of both IOLs was quite similar for 2.0 and 3.0 mm pupils. For 4.5-mm pupil, the EM Isopure showed a significant reduction of its optical quality in comparison with the monofocal IOL. When visual performance was evaluated, no statistically significant differences were found for any power of induced astigmatism. More differences were found when positive induced astigmatism was compared within each group, and VA was better when the astigmatism was induced at 180° vs. 90°. The greatest differences were found for and induced positive astigmatism of + 1.50D (p = 0.009 for Isopure and p = 0.023 for Micropure).
Conclusions: The tolerance to residual astigmatism of the EM Isopure lens is similar to that of a reference monofocal lens with pupils up to 3.5 mm.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00417-023-06305-9 | DOI Listing |
Diagnostics (Basel)
January 2025
Nobel Eye Institute, Taipei 10041, Taiwan.
: To evaluate the effectiveness of astigmatism correction between topographic- and manifest-based methods in individuals who underwent second-generation keratorefractive lenticule extraction (KLEx) surgery. : This study was conducted with participants who underwent second-generation KLEx surgery. After exclusion, there were 46 and 43 participants in the manifest and topographic groups, respectively.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Nobel Eye Institute, Taipei 10041, Taiwan.
: To evaluate the visual and refractive outcomes of keratorefractive lenticule extraction (KLEx) surgery and refractive lens exchange (RLE) surgery in moderate to high myopia patients. : A retrospective cohort study was performed, and patients receiving KLEx or RLE surgeries with myopia within -3.00 to -10.
View Article and Find Full Text PDFPurpose: To evaluate the clinical outcome of laser-assisted surgical correction of high hyperopic or mixed astigmatism using small incision intrastromal lenticule rotation (SMILERO) alone or combined with photorefractive keratectomy (PRK).
Methods: This retrospective case series enrolled 25 eyes with high astigmatism that underwent SMILERO surgery. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), manifest refraction, central corneal thickness, and corneal higher order aberrations were analyzed before surgery and after 3, 6, and 12 months of follow-up.
Purpose: To evaluate residual refractive errors after intraocular lens (IOL) extraction and the safety and effectiveness of refractive correction procedures.
Methods: The eligibility criteria for this systematic review were patients who had undergone cataract or clear lens extraction and had experienced residual refractive error. All study designs were considered for inclusion and non-English publications, non-peer reviewed articles, books, and systematic reviews were excluded.
Indian J Ophthalmol
January 2025
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India.
Scleral-fixated intraocular lens (SFIOL) is a widely used technique for IOL implantation in patients where capsular support is insufficient. Most surgeons have shifted away from sutured to sutureless SFIOL techniques where haptics of a multifocal IOL are inserted in scleral tunnels/flaps. Large-scale publications have shown wide variation in the refractive status of eyes post-SFIOL even in the best of the hands.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!