Objective: This prospective study of pregnant patients, Surveillance To Prevent AV Block Likely to Occur Quickly (STOP BLOQ), addresses the impact of anti-SSA/Ro titers and utility of ambulatory monitoring in the detection of fetal second-degree atrioventricular block (AVB).

Methods: Women with anti-SSA/Ro autoantibodies by commercial testing were stratified into high and low anti-52-kD and/or 60-kD SSA/Ro titers applying at-risk thresholds defined by previous evaluation of AVB pregnancies. The high-titer group performed fetal heart rate and rhythm monitoring (FHRM) thrice daily and weekly/biweekly echocardiography from 17-26 weeks. Abnormal FHRM prompted urgent echocardiography to identify AVB.

Results: Anti-52-kD and/or 60-kD SSA/Ro met thresholds for monitoring in 261 of 413 participants (63%); for those, AVB frequency was 3.8%. No cases occurred with low titers. The incidence of AVB increased with higher levels, reaching 7.7% for those in the top quartile for anti-60-kD SSA/Ro, which increased to 27.3% in those with a previous child who had AVB. Based on levels from 15 participants with paired samples from both an AVB and a non-AVB pregnancy, healthy pregnancies were not explained by decreased titers. FHRM was considered abnormal in 45 of 30,920 recordings, 10 confirmed AVB by urgent echocardiogram, 7 being second-degree AVB, all <12 hours from normal FHRM and within another 0.75 to 4 hours to echocardiogram. The one participant with second/third-degree and two participants with third-degree AVB were diagnosed by urgent echocardiogram >17 to 72 hours from an FHRM. Surveillance echocardiograms detected no AVB when the preceding interval FHRM recordings were normal.

Conclusion: High-titer antibodies are associated with an increased incidence of AVB. Anti-SSA/Ro titers remain stable over time and do not explain the discordant recurrence rates, suggesting that other factors are required. Fetal heart rate and rhythm (FHRM) with results confirmed by a pediatric cardiologist reliably detects conduction abnormalities, which may reduce the need for serial echocardiograms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11095662PMC
http://dx.doi.org/10.1002/art.42733DOI Listing

Publication Analysis

Top Keywords

avb
9
monitoring detection
8
atrioventricular block
8
anti-ssa/ro titers
8
anti-52-kd and/or
8
and/or 60-kd
8
60-kd ssa/ro
8
fetal heart
8
heart rate
8
rate rhythm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!