Background: Evidence regarding the implementation of medium-term strategies in advanced hybrid closed-loop (AHCL) system users is limited. Therefore, this study aimed to describe the efficacy and safety of the AHCL system in patients with type 1 diabetes (T1D) on a six-month follow-up in a virtual diabetes clinic (VDC).

Method: A prospective cohort of adult patients with T1D treated using the AHCL system (Mini Med 780G; Medtronic, Northridge, California) in a VDC follow-up. Standardized training and follow-up were conducted virtually. Clinical data and metabolic control outcomes were reported at baseline, and at three and six months.

Results: Sixty-four patients (mean age = 42 ± 14.6 years, 65% men, 54% with graduate education) were included. Percentage time in range (%TIR) increased significantly regardless of prior therapy with intermittently scanned continuous glucose monitoring + multiple daily injections and sensor-augmented pump therapy with predictive low-glucose management after starting AHCL and persisted during the follow-up period with no hypoglycemic events. The %TIR 70 to 180 mg/dL according to socioeconomic strata was 73.4% ± 5.3%, 78.1% ± 8.1%, and 84.2% ± 7.5% for the lower, middle, and upper strata, respectively. The sensor was used more frequently in the population with a higher education level. Adherence to sensor use and SmartGuard retention were higher in patients who underwent the VDC follow-up.

Conclusions: Medium-term follow-up of users of AHCL systems in a VDC contributes to safely achieving %TIR goals. Virtual diabetes clinic follow-up favored adherence to sensor use and continuous SmartGuard use. Socioeconomic strata were associated with a better glycemic profile and education level was associated with better adherence to sensor use.

Download full-text PDF

Source
http://dx.doi.org/10.1177/19322968231204376DOI Listing

Publication Analysis

Top Keywords

ahcl system
12
adherence sensor
12
clinic follow-up
8
advanced hybrid
8
hybrid closed-loop
8
virtual diabetes
8
diabetes clinic
8
socioeconomic strata
8
education level
8
associated better
8

Similar Publications

Comparison of the night-time effectiveness in achieving glycemic targets in adults with type 1 diabetes of three advanced hybryd closed-loop systems.

Acta Diabetol

November 2024

Unit of Endocrine Diseases and Diabetology, Department of Medicine, ASST Papa Giovanni XXIII, Piazza OMS, 1, 24127, Bergamo, Italy.

Article Synopsis
  • Advanced hybrid closed loop (AHCL) systems are the latest insulin therapy for adults with type 1 diabetes, aiming to assess their effectiveness during nighttime hours.
  • A study of 55 adults evaluated three AHCL systems (Minimed 780G, Tandem t:slim X2 with Control-IQ, and DBLG1) based on continuous glucose monitoring over 14 nights.
  • All systems met glycemic targets, but the Tandem t:slim X2 with Control-IQ system achieved a significantly higher percentage of time in range (TIR), suggesting better overall performance.
View Article and Find Full Text PDF

Background: Our objective was to assess the effect of a hybrid telemedicine approach, in conjunction with face-to-face follow-up, on the quality of life in recent users of an advanced hybrid closed-loop (AHCL) system.

Methods: A 1-year open randomized (1:1) clinical trial (ClinicalTrials.gov ID NCT04900636).

View Article and Find Full Text PDF

Introduction: The MiniMed™ 780G system is an advanced insulin pump system incorporating an AHCL (Advanced Hybrid Close Loop) algorithm that automatically adjusts insulin delivery based on glucose levels. All guidelines recommend the use of Automated Insulin Delivery therapy for people with type 1 diabetes (PWT1D) and they highlight that a specifically trained and expert team should provide training on HCL systems for PWT1D, but none of the publications detail the curriculum profile that diabetes educators should have. This paper aims to establish a consensus on the optimal educational pathway for diabetes educators on the MiniMed™ 780G system.

View Article and Find Full Text PDF

Background: Complexity of glucose regulation in persons with type 1 diabetes (PWDs) necessitates increased automation of insulin delivery (AID). This study aimed to analyze real-world data over 12 months from PWDs who started using the MiniMed 780G (MM780G) advanced hybrid closed-loop (aHCL) AID system at the Diabeter clinic, focusing on glucometrics and clinical outcomes.

Methods: Persons with type 1 diabetes switching to the MM780G system were included.

View Article and Find Full Text PDF

Introduction: Managing exercise remains challenging for adolescent athletes with type 1 diabetes (T1D), especially in contact sports. Even the use of hybrid closed loops can cause problems due to the need to disconnect the pump during some training or competitions. This study evaluated the efficacy of a novel protocol for the use of an advanced hybrid closed-loop system in adolescent football players with T1D during a sports camp.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!