AI Article Synopsis

  • Red blood cell wastage happens when blood is thrown away instead of being used for transfusions, often due to poor ordering practices; a new project aimed to improve this in a pediatric hospital using enhanced electronic ordering tools.
  • A team applied best practices and the Toyota Production System approach to revamp the blood ordering process, analyzing data for insights on how effective their changes were in reducing waste.
  • Results showed an 11% drop in unnecessary crossmatch procedures and a significant 77% reduction in red blood cell wastage; the analysis indicated a 61% decrease in expected waste due to their interventions.

Article Abstract

Background: Red blood cell wastage occurs when blood is discarded rather than transfused, and ineffective ordering results in unnecessary crossmatch procedures. We describe how a multimodal approach to redesigning electronic ordering tools improved blood utilization in a pediatric inpatient setting and how using innovative application of time series data analysis provides insights into intervention effectiveness, which can guide future process improvement cycles.

Methods: A multidisciplinary team used best practices and Toyota Production System methodology to redesign electronic blood ordering and improve administration processes. We analyzed crossmatch to transfusion ratio and red blood cell wastage time series data extracted from our laboratory information system and electronic health record. We used changepoint analysis to identify statistically discernible breaks in each time series, compatible with known interventions. We performed causal impact analysis on red blood cell wastage time series data to estimate blood wastage avoided due to the interventions.

Results: Changepoint analysis estimated an 11% decrease in crossmatch to transfusion ratio and a 77% decrease in red blood cell monthly wastage rate during the intervention period. Causal impact analysis estimated a 61% reduction in expected wastage compared to the scenario if the interventions had not occurred.

Discussion: Our results show that electronic health record design is an important factor in reducing waste and preventing unnecessary crossmatching, and that time series analysis can be a useful tool for evaluating the long-term impact of each stage of intervention in a longitudinal process redesign effort for the purpose of effectively targeting future improvement efforts.

Download full-text PDF

Source
http://dx.doi.org/10.1111/trf.17587DOI Listing

Publication Analysis

Top Keywords

time series
20
red blood
16
blood cell
16
cell wastage
12
series data
12
blood
10
electronic blood
8
blood ordering
8
blood utilization
8
utilization pediatric
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!