Small obstacles on the ground often lead to a fall when caught with commercial prosthetic feet. Despite some recently developed feet can actively control the ankle angle, for instance over slopes, their flat and rigid sole remains a cause of instability on uneven grounds. Soft robotic feet were recently proposed to tackle that issue; however, they lack consistent experimental validation. Therefore, this paper describes the experimental setup realized to test soft and rigid prosthetic feet with lower-limb prosthetic users. It includes a wooden walkway and differently shaped obstacles. It was preliminary validated with an able-bodied subject, the same subject walking on commercial prostheses through modified walking boots, and with a prosthetic user. They performed walking firstly on even ground, and secondly on even ground stepping on one of the obstacles. Results in terms of vertical ground reaction force and knee moments in both the sagittal and frontal planes show how the poor performance of commonly used prostheses is exacerbated in case of obstacles. The prosthetic user, indeed, noticeably relies on the sound leg to compensate for the stiff and unstable interaction of the prosthetic limb with the obstacle. Therefore, since the limitations of non-adaptive prosthetic feet in obstacle-dealing emerge from the experiments, as expected, this study justifies the use of the setup for investigating the performance of soft feet on uneven grounds and obstacle negotiation.

Download full-text PDF

Source
http://dx.doi.org/10.1109/ICORR58425.2023.10304763DOI Listing

Publication Analysis

Top Keywords

prosthetic feet
16
experimental setup
8
prosthetic
8
uneven grounds
8
prosthetic user
8
feet
7
setup test
4
test obstacle-dealing
4
obstacle-dealing capabilities
4
capabilities prosthetic
4

Similar Publications

Over 50% of individuals with lower limb loss report a fear of falling and avoiding daily activities partly due to a lack of plantar sensation. Providing direct somatosensory feedback via neural stimulation holds promise for addressing this issue. In this study, three individuals with lower limb loss received a sensory neuroprosthesis (SNP) that provided plantar somatosensory feedback corresponding to prosthesis-floor interactions perceived as arising from the missing foot generated by electrically activating the peripheral nerves in the residuum.

View Article and Find Full Text PDF

Design Optimization of the Mechanics of a Metamaterial-Based Prosthetic Foot.

Materials (Basel)

December 2024

Faculty of Mechanical Engineering, Poznan University of Technology, Piotrowo 3 Street, 61-138 Poznan, Poland.

This paper is dedicated to the analysis of a foot prosthesis optimization process, with a particular focus on the application of optimization algorithms and unconventional materials, such as auxetic materials. The study aims to enhance prosthesis performance by minimizing the difference between the ground reaction force generated by the prosthetic foot and that of a natural limb. In the initial part of the study, the basic topics concerning the parameterization of the foot prosthesis geometry and the preparation of a finite element model for human gait are discussed.

View Article and Find Full Text PDF

Following lower limb amputation residuum skin from the lower leg is used to reconstruct the residual limb. Unlike skin on the sole of the foot (plantar skin), leg skin is not inherently load bearing. Despite this, leg skin is required to be load bearing in the prosthetic socket.

View Article and Find Full Text PDF

Ankle-foot orthoses (AFOs) have been commonly prescribed for stroke survivors with foot drop, but their impact on the contractions of paretic tibialis anterior (TA) and medial gastrocnemius (MG) has remained inconclusive. This study thus investigated the effect of AFOs on these muscle contractions in stroke survivors. The contractions of paretic TA and MG muscles were assessed in twenty stroke patients and compared between walking with and without AFOs, using a novel wearable dynamic ultrasound imaging and sensing system.

View Article and Find Full Text PDF

Comparison of the effects of orthoses on hallux valgus angle and plantar pressure in individuals with hallux valgus.

Prosthet Orthot Int

December 2024

Department of Orthosis and Prosthetics, School of Health Sciences, Istanbul Medipol University, Istanbul, Turkey.

Background: Hallux valgus (HV) is a condition characterized by the lateral deviation of the first phalanx and medial deviation of the first metatarsal, leading to subluxation of the first metatarsophalangeal joint. Various orthotic applications are employed in the treatment of HV deformity. This study aimed to compare the effects of a toe separator (TS) and dynamic orthosis (DO) on hallux valgus angle (HVA), plantar pressure (PP), and quality of life (QoL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!