Shear bond strength characteristics on surface treatment modalities of CAD-CAM resin polymers.

J Prosthodont

Department of Restorative Dentistry, Graduate Prosthodontics OHSU, Portland, Oregon, USA.

Published: January 2025

Purpose: The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high-performance polymer material for fixed, screw-retained full arch restorations.

Material And Methods: A total of 135 computer-aided design and computer-aided manufacturing, high-performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm. The specimen surfaces were grouped as untreated (Group A), 50 μm Al2O3 (Group B), 110 μm Al2O3 (Group C), Rocatec (3 M, St. Paul, MN) activated with silica-modified alumina oxide treatment (Group D); and trimmed coarsely with a carbide bur (Group E). Group A samples were used as controls. After surface treatments, the specimens were gently cleansed with oil-free steam and alcohol wipes. Surface conditioning was performed on all physically treated samples.  The manufacturer's recommendations were followed for bonding composite resin to the samples with light-cured Visio.link (Bredent, Chesterfield, UK). Cylinders were veneered with composite resins (diameter 5 mm, height 4 mm) and polymerized on the specimen surfaces through plastic tubes. Twenty-seven specimens were used for each testing group and aging tests were performed. The experimental samples were thermocycled.  Shear bond strength and scanning electron microscopic tests were performed. Means and standard deviations were calculated.  Statistical analysis was performed with post-hoc Tukey tests.

Results: Statistical analysis revealed that there was a significant difference between the groups (p<0.001). The highest shear bond strengths were achieved for the specimens bonded with Visio.link without physical surface treatments (270.47 MPa). The lowest bond strengths were found for specimen surfaces abraded with 110 μm Al2O3 (117.03 Mpa) CONCLUSIONS: The results of this laboratory study indicated that the specimens used with Visio.link as provided by the manufacturer had the highest shear bond strengths between the composite resin and high-performance polymer test specimens. Modifications of the high-performance polymer surfaces with carbide burs did not change bonding strengths with the composite materials.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13790DOI Listing

Publication Analysis

Top Keywords

shear bond
12
bond strength
12
composite resin
8
high-performance polymer
8
10 mm 10 mm
8
specimen surfaces
8
μm al2o3
8
al2o3 group
8
tests performed
8
statistical analysis
8

Similar Publications

The iron-regulated surface determinant protein B (IsdB) has recently been shown to bind to toll-like receptor 4 (TLR4), thereby inducing a strong inflammatory response in innate immune cells. Currently, two unsolved questions are (i) What is the molecular mechanism of the IsdB-TLR4 interaction? and (ii) Does it also play a role in nonimmune systems? Here, we use single-molecule experiments to demonstrate that IsdB binds TLR4 with both weak and extremely strong forces and that the mechanostability of the molecular complex is dramatically increased by physical stress, sustaining forces up to 2000 pN, at a loading rate of 10 pN/s. We also show that TLR4 binding by IsdB mediates time-dependent bacterial adhesion to endothelial cells, pointing to the role of this bond in cell invasion.

View Article and Find Full Text PDF

Outcome of Er, Cr:YSGG laser and antioxidant pretreatments on bonding quality to caries-induced dentin.

BMC Oral Health

January 2025

Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Future University, Cairo, Egypt.

Background: This study aimed to assess the influence of different pretreatment protocols and antioxidants application on the shear bond strength (SBS) of universal adhesive to sound (SoD) and caries-induced dentin (CID).

Methods: One hundred and twenty posterior teeth had their occlusal enamel removed, then the specimens were divided into two main groups according to dentin substrates; SoD and CID, three subgroups according to pretreatments protocols control (no pretreatment), NaOCl-treated, and Er, Cr:YSGG-treated and two divisions according to antioxidant application (with and without sodium ascorbate (SA) application). All-Bond Universal (ABU) universal adhesives was applied in self-etch (SE) mode then resin composite discs were built.

View Article and Find Full Text PDF

Objective: To evaluate the influence of different cleaning methods, surface treatments, and aging on the repair bond strength to a CAD/CAM glass-ceramic.

Materials And Methods: Forty-eight lithium disilicate CAD/CAM ceramic blocks were fabricated, sintered, and embedded in acrylic resin. After contamination with human saliva, they were divided according to the factors "Cleaning method" (Control-water/air spray, Air-particle abrasion with AlO, Ivoclean cleaning paste), "Surface treatment" (5% Hydrofluoric acid-HF + Silane, Monobond Etch & Prime-MEP), and "Aging" (thermocycling, no thermocycling).

View Article and Find Full Text PDF

A Mutant Complement Factor H (W1183R) Enhances Proteolytic Cleavage of von Willebrand Factor by ADAMTS13 Under Shear.

J Thromb Haemost

January 2025

Department of Pathology and Laboratory Medicine; Institute of Reproductive Medicine and Developmental Sciences, The University of Kansas Medical Center, Kansas City, KS 66160. Electronic address:

Background: A loss-of-functional mutation (W1183R) in human complement factor H (CFH) is associated with complement-associated hemolytic uremic syndrome; mice carrying a similar mutation (W1206R) in CFH also develop thrombotic microangiopathy but its plasma von Willebrand factor (VWF) multimer sizes were dramatically reduced. The mechanism underlying such a dramatic change in plasma VWF multimer distribution in these mice is not fully understood.

Objective And Methods: To determine the VWF and CFH interaction and how CFH proteins affect VWF multimer distribution, we employed recombinant protein expression, purification, and various biochemical and biophysical tools.

View Article and Find Full Text PDF

Polyurea (PUR) has been widely used as a protective coating in recent years. In order to complete the understanding of the relationship between PUR microstructure and its energy absorption capabilities, the mechanical and dynamic performance of PURs containing various macrodiol structural units were compared using material characterization techniques and molecular dynamic simulation. The results showed that the PUR polycarbonate diols formed as energy absorbing materials showed high tensile strength, high toughness, and excellent loss factor distribution based on the comparison of stress-strain tensile curves, glass transition temperatures, phase images, and dynamic storage loss modulus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!