An increasing number of patients undergoing elective or emergency surgery in the United States have a cardiovascular implantable electronic device. Practice advisories and consensus statements have been issued by the American Society of Anesthesiologists and the Heart Rhythm Society, advocating a multidisciplinary approach. Unfortunately, anesthesia providers often find themselves in a situation in which they are left to manage these devices independently. At the University of Washington Medical Center, an anesthesiology-based service to manage these devices has existed for more than a decade. Many problems with devices have been observed, including confusing rhythms, failure of magnets to provide the desired change in device function, and actual device malfunction. With these clinical case examples taken from the authors' collective experience, this article provides an in-depth understanding of some key electrophysiology principles relevant to cardiovascular implantable electronic device function and appropriate perioperative management.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/j.jvca.2023.09.035 | DOI Listing |
Neth Heart J
January 2025
Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Centre, Maastricht, The Netherlands.
The European Society of Cardiology (ESC) has updated its guidelines on cardiac pacing and cardiac resynchronisation. As the majority are class II recommendations (61%) and based on expert opinion (59%), a critical appraisal for the Dutch situation was warranted. A working group has been established, consisting of specialists in cardiology, cardiothoracic surgery, geriatrics, allied professionals in cardiac pacing, and patient organisations with support from the Knowledge Institute of the Dutch Association of Medical Specialists.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Department of Cardiology, Boston Children's Hospital and Department of Pediatrics, Harvard Medical School, Boston, MA, 02115, USA.
The number of children with cardiac implantable electronic devices (CIEDs) is increasing at a time of rapid growth in cardiac magnetic resonance (MR) and cardiac computed tomography (CT) utilization. The presence of CIEDs poses challenges with respect to imaging safety and quality. A thoughtful approach to cardiovascular imaging in patients with CIEDs begins with an awareness of the clinical indications to determine the most appropriate imaging modality.
View Article and Find Full Text PDFFront Med (Lausanne)
January 2025
Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, China.
Background: Acute type A aortic dissection (ATAAD) is a life-threatening condition that often requires total aortic arch replacement (TAR) combined with frozen elephant trunk (FET) implantation. Despite advancements in surgical techniques and preoperative management, postoperative acute kidney injury (AKI) remains a prevalent complication that significantly affects patient prognosis, particularly severe AKI. The aim of this study was to investigate the predictive value of perioperative lactate levels in severe postoperative AKI after TAR.
View Article and Find Full Text PDFCureus
December 2024
Department of Clinical Research and Quality Management, Graduate School of Medicine, University of the Ryukyus, Okinawa, JPN.
Background Patients undergoing transcatheter aortic valve implantation (TAVI) are often elderly, and perioperative and long-term risk assessments should primarily consider cognitive function, comorbidities, and procedural complexity. This study investigated the association between cognitive function and mortality in patients with severe aortic valve stenosis (AS) who underwent TAVI. Methodology This single-center, retrospective cohort study consecutively registered patients who underwent TAVI between December 2014 and December 2018.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
The extracellular matrix (ECM) is a complex and dynamic three-dimensional network that functions as an architectural scaffold to maintain cardiac homeostasis. Important biochemical and mechanical signals associated with cell‒cell communication are provided via the reciprocal interaction between cells and the ECM. By converting mechanical cues into biochemical signals, the ECM regulates many cell processes, including migration, adhesion, growth, differentiation, proliferation, and apoptosis.