Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Ambient liquid extraction techniques enable direct mass spectrometry imaging (MSI) under ambient conditions with minimal sample preparation. However, currently an integrated probe for ambient liquid extraction-based MSI with high spatial resolution, high sensitivity, and stability is still lacking. In this work, we developed a new integrated probe made of pulled coaxial capillaries, named pulled flowprobe, and compared it with the previously reported single-probe. Mass transfer kinetics in probes was first investigated. The extraction kinetic curves during probe sampling indicate a narrower and higher peak shape for the pulled flowprobe than single-probe. Computational fluid dynamics analysis reveals that in the pulled flowprobe flow velocities are lower in liquid microjunction and higher in the transferring channels, resulting in higher extraction efficiencies and reduced band diffusion compared with single-probe and other probes with a similar flow route. Results of ambient liquid extraction-based MSI of lipids in rat cerebrum show that signals of low-abundance lipids were 2-5 times higher via a pulled flowprobe than via a single-probe, and 26 more lipid species were detected on brain tissue via a pulled flowprobe than via a single-probe. The stability of MSI with the pulled flowprobe was found to be higher than that with single-probe (averaged relative standard deviation = 18% vs 80%) by imaging a lab-made uniform ink coating. Moreover, in the pulled flowprobe, no retraction of the inner capillary from outer capillary is optimal for both sensitivity and stability. The spatial resolution of the pulled flowprobe (30-40 μm) was measured to be higher than that of a comparable size single-probe by calculation with the "80-20" rule. Finally, the new pulled flowprobe was applied to high-resolution MSI of lipids in the hippocampus, and localization of several lipids to the specific cell layers in the hippocampus region was observed. Thus, this work provides an alternative easily fabricated sampling probe with enhanced sensitivity, stability, and spatial resolution, promoting the use of ambient liquid extraction-based MSI in biological and clinical research.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.3c03046 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!