Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The suprascapular notch lies in the superior border of the scapula and is a passageway for the suprascapular nerve that is sensory to the shoulder joint. Suprascapular nerve block involves injection of local anaesthetic into the suprascapular notch, either ultrasound guided or blind, using the spine of scapula and/or the medial border of the acromion as surface landmarks.
Aim: To investigate the anatomic variations that exist between the distance of the notch from the spine of scapula and acromion.
Method: Ninety-two dry scapulae were measured with a digital calliper for their length of the spine, distance between the midpoint of the spine and base of the suprascapular notch and distance between the medial border of the acromion and the base of the suprascapular notch. These measurements were compared for variations in the scapular bony landmarks, the spine and the acromion to determine the site for the injection.
Results: Measurement reliability was assessed by intraclass correlation, Cronbach's alpha being 0.99, 0.97 and 0.91 for length of spine, distance from spine and distance from acromion respectively. The distance from the acromion had less variation in measurement (3.73 ± 0.42 cm) but a flatter distribution when compared to distance from the spine of the scapula (3.32 ± 0.39 cm).
Conclusion: Length of the spine of the scapula appeared not to influence either distance from the acromion or distance from the spine of scapula. There is potential for greater variability in placement of nerve blocks that use acromion as the bony reference. Key Points • Dry scapular measurement using electronic Vernier callipers is accurate (0.91-0.97). • There is potential for greater variability in placement of blind nerve blocks that use acromion as the bony reference to locate the suprascapular notch.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10774181 | PMC |
http://dx.doi.org/10.1007/s10067-023-06807-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!