A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimation of radiation dose due to thoron and progeny inhalation in high background natural radiation area of Odisha, India. | LitMetric

Results of the preliminary measurements of indoor radon, thoron and progeny concentrations showed very high values of thoron concentrations in the eastern coastal region of Odisha, India. Therefore, measurements of thoron and its progeny concentrations were extended to a larger number of houses in this area for the assessment of the radiation dose received by the public. The measured values of thoron concentrations were used for the calculation of annual effective doses. The estimated values of the annual effective dose due to thoron exposure were observed in the range of 0.2-14.7 mSv. The estimated radiation doses responsible for thoron exposure were observed considerably high in the region. The results obtained are compared with those obtained in other studies performed so far in the study area and a review of different studies involving different measurement techniques is presented in the paper. The results of this study support the preliminary studies showing high values of thoron levels in the study area.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncad173DOI Listing

Publication Analysis

Top Keywords

thoron progeny
12
values thoron
12
radiation dose
8
thoron
8
dose thoron
8
odisha india
8
progeny concentrations
8
high values
8
thoron concentrations
8
annual effective
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!