AI Article Synopsis

  • * During the 2019 NASA ARADS campaign, the SOLID-LDChip was used on a rover to autonomously search for molecular biomarkers in soil samples drilled up to 80 cm deep.
  • * Results showed a rich microbial community and highlighted the chip’s effectiveness, paving the way for future missions focused on life detection in the Solar System.

Article Abstract

The low organic matter content in the hyperarid core of the Atacama Desert, together with abrupt temperature shifts and high ultraviolet radiation at its surface, makes this region one of the best terrestrial analogs of Mars and one of the best scenarios for testing instrumentation devoted to planetary exploration. We have operated remotely and autonomously the SOLID-LDChip (Signs of Life Detector-Life Detector Chip), an antibody microarray-based sensor instrument, as part of a rover payload during the 2019 NASA Atacama Rover Astrobiology Drilling Studies (ARADS) Mars drilling simulation campaign. A robotic arm collected drilled cuttings down to 80 cm depth and loaded SOLID to process and assay them with LDChip for searching for molecular biomarkers. A remote science team received and analyzed telemetry data and LDChip results. The data revealed the presence of microbial markers from Proteobacteria, Acidobacteria, Bacteroidetes, Actinobacteria, Firmicutes, and Cyanobacteria to be relatively more abundant in the middle layer (40-50 cm). In addition, the detection of several proteins from nitrogen metabolism indicates a pivotal role in the system. These findings were corroborated and complemented on "returned samples" to the lab by a comprehensive analysis that included DNA sequencing, metaproteomics, and a metabolic reconstruction of the sampled area. Altogether, the results describe a relatively complex microbial community with members capable of nitrogen fixation and denitrification, sulfur oxidation and reduction, or triggering oxidative stress responses, among other traits. This remote operation demonstrated the high maturity of SOLID-LDChip as a powerful tool for remote life detection for future missions in the Solar System.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10825288PMC
http://dx.doi.org/10.1089/ast.2021.0174DOI Listing

Publication Analysis

Top Keywords

life detection
8
signs life
8
life detector-life
8
detector-life detector
8
detector chip
8
mars drilling
8
drilling simulation
8
simulation campaign
8
hyperarid core
8
core atacama
8

Similar Publications

Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar.

View Article and Find Full Text PDF

Prostate cancer (PCa) is prevalent among men over 70. Treatment may involve interventions like radical prostatectomy. The objective of this study was to investigate the combination of adverse pathology patterns on PCa progression through the Briganti 2012 nomogram and EAU risk classes in elderly patients treated with robotic surgery.

View Article and Find Full Text PDF

Evaluation of Plasma microRNA-222 as a Biomarker for Gastric Cancer.

J Clin Med

December 2024

Department of Surgery, Toho University Sakura Medical Center, 564-1 Shimoshizu, Sakura 285-8741, Chiba, Japan.

The dysregulation of microRNAs (miRNAs) has been detected in patients with gastric cancer (GC), which inspired the use of miRNAs as a novel biomarker for GC. In this study, we investigated the previously reported miRNA dysfunction in cancer tissues as a potential plasma biomarker for GC using quantitative reverse transcriptase polymerase chain reaction (RT-PCR). The published miRNA abnormalities were searched in the microRNA Cancer Association Database.

View Article and Find Full Text PDF

Laboratory Assessment of Factor VIII Inhibitors: When Is It Required? A Perspective Informed by Local Practice.

J Clin Med

December 2024

Haematology, Sydney Centres for Thrombosis and Haemostasis, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW 2145, Australia.

This perspective discusses the critical role of laboratory assessments in assessing factor VIII (FVIII) inhibitors. These are auto- and alloantibodies that can develop against both endogenous and exogenous FVIII, respectively. Assessment for inhibitors represents a key part of the management of both congenital hemophilia A (CHA), an inherited deficiency, and acquired hemophilia A (AHA), an autoimmune condition.

View Article and Find Full Text PDF

Digital Health Technologies for Optimising Treatment and Rehabilitation Following Surgery: Device-Based Measurement of Sling Posture and Adherence.

Sensors (Basel)

December 2024

Assessment of Movement Behaviours (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK.

Background: Following shoulder surgery, controlled and protected mobilisation for an appropriate duration is crucial for appropriate recovery. However, methods for objective assessment of sling wear and use in everyday living are currently lacking. In this pilot study, we aim to determine if a sling-embedded triaxial accelerometer and/or wrist-worn sensor can be used to quantify arm posture during sling wear and adherence to sling wear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!