A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical behavior of carbon fiber-reinforced polyetheretherketone as a dental implant material in implant-supported overdenture under mandibular trauma: A finite element analysis study. | LitMetric

Context: Implant-supported overdentures are well-known and widely accepted treatment modality to increase retention which is a crucial factor for determining patient satisfaction. The placement of two implants in the anterior region can be selected as a first-line treatment in patients with the atrophic mandibular ridge.

Aims: The purpose of this research was to assess the biomechanical effects of carbon fiber-reinforced polyetheretherketone (CFR-PEEK) implant-supported overdenture in the event of 2,000 N forefront trauma to an atrophic edentulous mandible by using the finite element analysis method.

Materials And Methods: Three types of mandible models were simulated; the first one was an edentulous atrophic mandible model; in the second model, 3.5 × 11.5 mm CFR-PEEK implants; and in the third model, 4.3 × 11.5 mm CFR-PEEK implants were positioned in the region of the lateral incisor of the identical edentulous atrophic mandible.

Results: Maximum Von Misses stresses 979.261 MPa, 1,454.69 MPa, and 1,940.71 MPa and maximum principal stresses 1,112.74 MPa, 1,249.88 MPa, and 1,251.33 MPa have been detected at the condylar neck area and minimum principal stresses - 1,203.38 MPa, -1,503.21 MPa, and - 1,990.34 MPa have been recorded at the symphysis and corpus regions from M1 to M3, respectively. In addition, the M2 and M3 models showed low-stress distributions around the implant-bone interface, particularly where the implants were in contact with cancellous bone.

Conclusions: The results showed that the insertion of different diameters of CFR-PEEK implants led to low and homogenous stress distribution all around the implant-bone interface and stresses transferred directly to the condylar neck areas. Therefore, it was observed that CRF-PEEK implants did not change the basic behavior of the mandibula in response to frontal stresses.

Download full-text PDF

Source
http://dx.doi.org/10.4103/njcp.njcp_239_23DOI Listing

Publication Analysis

Top Keywords

cfr-peek implants
12
mpa
9
carbon fiber-reinforced
8
fiber-reinforced polyetheretherketone
8
implant-supported overdenture
8
finite element
8
element analysis
8
edentulous atrophic
8
model 115
8
115 cfr-peek
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!