A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments. | LitMetric

Assessment of diastasis recti abdominis: Clinimetric properties of four measuring instruments.

Int J Health Sci (Qassim)

Department of Medical Rehabilitation, Faculty of Health Sciences and Technology, University of Nigeria, Enugu, Nigeria.

Published: January 2023

Objective: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging.

Methods: Ninety consenting parous women (20-45 years), recruited from a postnatal clinic in Enugu, Nigeria, participated in this observational study. Two physiotherapists and a sonographer measured their inter rectus distance at the level of the umbilicus, 4.5 cm above and below it, respectively, using each of the four modalities. The intra-rater measurements were taken at a week's interval. Data were analyzed with descriptive and inferential statistics of intraclass correlation coefficient and paired samples T-test, at an alpha level set at < 0.05.

Results: It showed the palpation technique (r = 0.749-0.967 and 0.658-0.917), digital calipers (r=0.750-0.955 and 0.685-0.904), and diastometer (r=0.762-0.958 and 0.471-0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points.

Conclusion: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10624799PMC

Publication Analysis

Top Keywords

palpation technique
16
digital calipers
16
technique digital
12
calipers diastometer
12
concurrent validity
8
assessment diastasis
4
diastasis recti
4
recti abdominis
4
abdominis clinimetric
4
clinimetric properties
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!