A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility and safety of 0.6% sodium alginate in endoscopic submucosal dissection for colorectal neoplastic lesion: A pilot study. | LitMetric

Objectives: The usefulness of 0.6% sodium alginate (SA) as a submucosal (SM) injection solution for endoscopic SM dissection (ESD) has gained attention over the past few years. However, using ESD for colorectal neoplastic lesions is not explicitly researched as yet. Thus, we conducted this study to determine the feasibility and safety of 0.6% SA solution for colorectal ESD.

Methods: In this single-center, retrospective pilot study, a total of 100 cases treated with ESD using 0.6% SA as a SM injection solution for colorectal neoplasia at our institute were retrospectively reviewed to clarify the clinical feasibility and safety of 0.6% SA. The primary endpoint was to evaluate the complication rate, and the secondary endpoint was to determine the procedure time and the amount of solution used.

Results: Intraoperative perforation was observed in 1 case (1.0%), 2 cases (2.0%) presented with postprocedural hemorrhage, and no lethal adverse events were observed. The median ESD procedure times were 39.5 min (10-150), and the amount of solution used was less than 20 mL in 67 cases (67.0%). En-bloc resection could be achieved in 97 cases (97.0%). Although six cases underwent subsequent surgery due to the deep SM invasion (>1000 μm), there were no cases with nodal involvement, confirmed through histopathological evaluation.

Conclusions: Our findings indicate that 0.6% SA can potentially ensure safe and secure ESD for colorectal neoplasia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10625103PMC
http://dx.doi.org/10.1002/deo2.313DOI Listing

Publication Analysis

Top Keywords

feasibility safety
12
safety 06%
12
06% sodium
8
sodium alginate
8
colorectal neoplastic
8
pilot study
8
injection solution
8
esd colorectal
8
solution colorectal
8
colorectal neoplasia
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!