3D multi-modality Transformer-GAN for high-quality PET reconstruction.

Med Image Anal

School of Electrical and Information Engineering, University of Sydney, Australia. Electronic address:

Published: January 2024

Positron emission tomography (PET) scans can reveal abnormal metabolic activities of cells and provide favorable information for clinical patient diagnosis. Generally, standard-dose PET (SPET) images contain more diagnostic information than low-dose PET (LPET) images but higher-dose scans can also bring higher potential radiation risks. To reduce the radiation risk while acquiring high-quality PET images, in this paper, we propose a 3D multi-modality edge-aware Transformer-GAN for high-quality SPET reconstruction using the corresponding LPET images and T1 acquisitions from magnetic resonance imaging (T1-MRI). Specifically, to fully excavate the metabolic distributions in LPET and anatomical structural information in T1-MRI, we first use two separate CNN-based encoders to extract local spatial features from the two modalities, respectively, and design a multimodal feature integration module to effectively integrate the two kinds of features given the diverse contributions of features at different locations. Then, as CNNs can describe local spatial information well but have difficulty in modeling long-range dependencies in images, we further apply a Transformer-based encoder to extract global semantic information in the input images and use a CNN decoder to transform the encoded features into SPET images. Finally, a patch-based discriminator is applied to ensure the similarity of patch-wise data distribution between the reconstructed and real images. Considering the importance of edge information in anatomical structures for clinical disease diagnosis, besides voxel-level estimation error and adversarial loss, we also introduce an edge-aware loss to retain more edge detail information in the reconstructed SPET images. Experiments on the phantom dataset and clinical dataset validate that our proposed method can effectively reconstruct high-quality SPET images and outperform current state-of-the-art methods in terms of qualitative and quantitative metrics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.media.2023.102983DOI Listing

Publication Analysis

Top Keywords

spet images
16
images
10
transformer-gan high-quality
8
high-quality pet
8
lpet images
8
high-quality spet
8
local spatial
8
pet
5
spet
5
multi-modality transformer-gan
4

Similar Publications

: Paediatric PET/CT imaging is crucial in oncology but poses significant radiation risks due to children's higher radiosensitivity and longer post-exposure life expectancy. This study aims to minimize radiation exposure by generating synthetic CT (sCT) images from emission PET data, eliminating the need for attenuation correction (AC) CT scans in paediatric patients. : We utilized a cohort of 128 paediatric patients, resulting in 195 paired PET and CT images.

View Article and Find Full Text PDF

We compared and analyzed the consistency and repeatability of left and right ventricular ((LV/RV) functions obtained by gated-equilibrium radionuclide ventriculography (ERNV) with cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT) and conventional SPECT (C-SPECT) with sodium iodide crystal detectors. Seventy-seven patients were included in the retrospective study. Both C-SPECT and CZT-SPECT imaging were performed on the same day.

View Article and Find Full Text PDF

To obtain high-quality positron emission tomography (PET) images while minimizing radiation exposure, numerous methods have been dedicated to acquiring standard-count PET (SPET) from low-count PET (LPET). However, current methods have failed to take full advantage of the different emphasized information from multiple domains, i.e.

View Article and Find Full Text PDF
Article Synopsis
  • This study examined the relationship between the SP-ET index (the patella-femoral trochlea distance ratio) and chondromalacia patella (CP) using MRI data from 348 knees belonging to 308 patients.
  • Two reviewers analyzed these measurements, finding excellent agreement on the values calculated, and concluded that patients with CP had significantly higher SP-ET index values compared to those without CP.
  • The findings suggest a strong correlation between the SP-ET index and the severity of CP across different demographics, indicating its potential as a useful diagnostic tool.
View Article and Find Full Text PDF

3D multi-modality Transformer-GAN for high-quality PET reconstruction.

Med Image Anal

January 2024

School of Electrical and Information Engineering, University of Sydney, Australia. Electronic address:

Positron emission tomography (PET) scans can reveal abnormal metabolic activities of cells and provide favorable information for clinical patient diagnosis. Generally, standard-dose PET (SPET) images contain more diagnostic information than low-dose PET (LPET) images but higher-dose scans can also bring higher potential radiation risks. To reduce the radiation risk while acquiring high-quality PET images, in this paper, we propose a 3D multi-modality edge-aware Transformer-GAN for high-quality SPET reconstruction using the corresponding LPET images and T1 acquisitions from magnetic resonance imaging (T1-MRI).

View Article and Find Full Text PDF