AI-Supported Autonomous Uterus Reconstructions: First Application in MRI Using 3D SPACE with Iterative Denoising.

Acad Radiol

Department of Radiology, Kantonsspital Baden, Im Ergel 1, Baden, 5404, Switzerland (D.H., A.L., M.F., M.G., K.H.).

Published: April 2024

Rationale And Objectives: T2-weighted imaging in at least two orthogonal planes is recommended for assessment of the uterus. To determine whether a convolutional neural network-based algorithm could be used for the re-constructions of uterus axes derived from a 3D SPACE with iterative denoising.

Materials And Methods: 50 patients aged 18-81 (mean: 42) years who underwent an MRI examination of the uterus participated voluntarily in this prospective study after informed consent. In addition to a standard MRI pelvis protocol, a 3D SPACE research application sequence was acquired in sagittal orientation. Reconstructions for both the cervix and the cavum in the short and long axes were performed by a research trainee (T), an experienced radiologist (E), and the prototype software (P). In the next step, the reconstructions were evaluated anonymously by two experienced readers according to 5-point-Likert-Scales. In addition, the length of the cervical canal, the length of the cavum and the distance between the tube angles were measured on all reconstructions. Interobserver agreement was assessed for all ratings.

Results: For all axes, significant differences were found between the scores of the reconstructions by research T, E and P. P received higher scores and was preferred significantly more often with the exception of the comparison of the reconstruction Cervix short of E (Cervix short: P vs. T: p = 0.02; P vs. E: p = 0.26; Cervix long: P vs. T: p = 0.01; P vs. E: p < 0.01; Cavum short: P vs. T: p = 0.01; P vs. E: p = 0.02; Cavum long: P vs. T: p < 0.01; P vs. E: p < 0.01). Regarding the measured diameters, (length of cervical canal/cavum/distance between tube angles) significantly larger diameters were recorded for P compared to E and T (Cervix long (mm): T: 25.43; E: 25.65; P: 26.65; Cavum short (mm): T: 26.24; E: 25.04; P: 27.33; Cavum long (mm): T: 31.98; E: 32.91; P: 34.41; P vs. T: p < 0.01); P vs. E: p = 0.04). Moderate to substantial agreement was found between Reader 1 and Reader 2 (range: 0.39-0.67).

Conclusion: P was able to reconstruct the axes at least as well as or better than E and T. P could thereby lead to workflow facilitation and enable more efficient reporting of uterine MRI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2023.09.035DOI Listing

Publication Analysis

Top Keywords

space iterative
8
cervix short
8
reconstructions
5
ai-supported autonomous
4
uterus
4
autonomous uterus
4
uterus reconstructions
4
reconstructions application
4
application mri
4
mri space
4

Similar Publications

Proteomic diversity in bacteria: Insights and implications for bacterial identification.

Mol Cell Proteomics

January 2025

Bavarian Center for Biomolecular Mass Spectrometry (BayBioMS), TUM School of Life Sciences, Technical University of Munich, 85354 Freising, Germany. Electronic address:

Mass spectrometry-based proteomics has revolutionized bacterial identification and elucidated many molecular mechanisms underlying bacterial growth, community formation, and drug resistance. However, most research has been focused on a few model bacteria, overlooking bacterial diversity. In this study, we present the most extensive bacterial proteomic resource to date, covering 303 species, 119 genera, and five phyla with over 636,000 unique expressed proteins, confirming the existence of over 38,700 hypothetical proteins.

View Article and Find Full Text PDF

This paper proposes a covert chaotic encryption (CCE) scheme based on compressive sensing (CS). The chaotic sequences used are generated by a six-dimensional hyper-chaotic D-system, where the sequence is utilized for a chaotic index sparse block (CISB), the sequence is used for generating the CS measurement matrix effectively, the , , and sequences are employed for variable-parameter iterative Arnold transformations, and the sequence is used for dual-random least significant bit (LSB) scrambling and embedding. The combination of these technologies enabled the scheme to achieve multi-domain, multi-dimensional, ultra-high-security encryption for multimedia image data.

View Article and Find Full Text PDF

Three-dimensional (3D) light-field displays can provide natural stereoscopic visual perception and an intuitive viewing experience. However, the high production threshold and the lack of user-friendly editing tools for light-field images make it difficult to efficiently and conveniently generate 3D light-field content that meets various needs. Here, a text-driven light-field content editing method for 3D light-field display based on Gaussian splatting is presented.

View Article and Find Full Text PDF

High-quality light-field generation of real scenes based on view synthesis remains a significant challenge in three-dimensional (3D) light-field displays. Recent advances in neural radiance fields have greatly enhanced light-field generation. However, challenges persist in synthesizing high-quality cylindrical viewpoints within a short time.

View Article and Find Full Text PDF

This paper reports the proton response function for solution-grown trans-stilbene scintillator from 1 to 25 MeVee and its application for unfolding neutron spectra of Cf-252 and AmBe sources. Low energy proton response was measured by the Time-of-Flight technique at the Korea Research Institute of Standards and Science. In contrast, high energy response was investigated using a 45 MeV proton beam at the Korea Institute of Radiological & Medical Sciences.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!