Total knee arthroplasty (TKA) is one of the most frequently performed interventions in the field of Orthopaedic surgery. Over the last decades the implantation technique has improved continuously. The majority of patients is satisfied with the clinical outcome of TKA. However in various clinical follow-ups, up to 20% of unsatisfied patients can be observed. Periprosthetic infection and aseptic loosening seem to be the most common reasons for failure. Malalignment has been discussed as a cause of aseptic loosening and often leads to revision surgery. In order to increase the precision of implant positioning and alignment, new technologies such as patient-specific instrumentation (PSI) have been developed. Since the introduction of PSI, multiple clinical studies have been performed analyzing the clinical and radiological outcome of TKA with PSI technique. This review covers the recent literature of PSI in respect to surgical accuracy, clinical outcome, time- and cost-effectiveness.

Download full-text PDF

Source
http://dx.doi.org/10.52628/89.2.11543DOI Listing

Publication Analysis

Top Keywords

patient-specific instrumentation
8
total knee
8
knee arthroplasty
8
clinical outcome
8
outcome tka
8
aseptic loosening
8
clinical
5
instrumentation total
4
arthroplasty review
4
review current
4

Similar Publications

Purpose: Achieving precise postoperative alignment is critical for the long-term success of total knee arthroplasty (TKA). Long-leg standing radiograph (LLR) at 6 weeks post-op is the gold standard for assessing alignment, but its reliance on weight-bearing and positioning makes it less practical in the early postoperative period. Supine computed tomography scanogram (CTS) offers a potential alternative.

View Article and Find Full Text PDF

Background: Patellar fractures present challenges in treatment, with traditional methods often leading to complications such as loss of reduction and implant failure. This study aimed to compare a novel suture fixation technique with the traditional tension band method using finite element analysis.

Methods: CT images of a healthy 35-year-old male were used to construct 3D patellar models.

View Article and Find Full Text PDF

Purpose: The aim of the study was to determine preoperative patient- and fracture-related risk factors for estimating the risk of fracture sequelae after surgically treated proximal humerus fractures (PHF) using locking plate osteosynthesis. The purpose was to develop a fracture sequelae risk score as an additional tool to facilitate the treatment strategy for PHF.

Methods: All patients with PHF who underwent surgery with locking plate osteosynthesis were included.

View Article and Find Full Text PDF

Alternatives for exhausted dialysis access.

Semin Vasc Surg

December 2024

Department of Surgery, Division of Vascular and Endovascular Surgery, Duke University Medical Center, Durham, NC. Electronic address:

Hemodialysis (HD) access failure is a frequent problem encountered by vascular surgeons. As treatment of end-stage renal disease improves and patients live longer on HD, eventual exhaustion of traditional upper extremity HD access is common. Efforts to preserve and maintain these accesses are essential.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!