A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical outcomes of MANTA closure device in percutaneous endovascular aortic aneurysm repair. | LitMetric

Objective: The MANTA device is a plug-based vascular closure device (VCD) designed for large bore femoral arterial access site closure. It showed promising results in transcatheter aortic valve replacement cases. In this study, we report our results and evaluate the MANTA VCD in percutaneous endovascular aortic aneurysm repair (pEVAR).

Methods: All data of consecutive patients who underwent an elective pEVAR between October 2018 and December 2022 were retrospectively reviewed. In all patients at least one common femoral artery was intended to close with the MANTA VCD. Depending on the sheath size, the 14Fr or 18Fr MANTA VCD was used. On the preoperative computed tomography scan, the diameter of the common femoral artery (CFA) was measured and the amount of calcification based on the Peripheral Arterial Calcium Scoring System (PACSS) was scored. Primary outcome was procedural technical success. Procedural technical success was defined as placement of the MANTA closure device resulting in vascular closure with patent CFA, without requiring immediate open or endovascular surgery. The secondary outcomes were access site complications requiring reintervention and all-cause mortality at 30-day follow-up.

Results: In total, 152 consecutive patients underwent pEVAR with 291 common femoral artery closure procedures with the Manta VCD. Mean age was 74.1 ± 6.4 years, with a mean body mass index of 27.7 ± 4.4 kg/m. The mean diameter of the CFA was 10.5 ± 1.9 mm. In 52.6% of the cases, there were no calcification on the preoperative computed tomography scan. The 18Fr and 14Fr Manta VCD were used 169 and 122 times, respectively. The technical success rate was 96.6%. Major vascular complications were reported in 4.5% of the cases, without any death-related events.

Conclusions: This single-center retrospective cohort study analyzed the procedural technical success, major vascular complications and all-cause mortality at 30-day follow-up of the MANTA vascular closure device in 152 pEVAR patients with 291 common femoral artery closure procedures. The technical success rate was 96,6%. Major vascular complications were reported in 4.5% of the cases, without any death related events. We concluded that the MANTA device is a safe and feasible option with a high rate of technical success in patients undergoing pEVAR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2023.10.054DOI Listing

Publication Analysis

Top Keywords

technical success
24
manta vcd
20
closure device
16
common femoral
16
femoral artery
16
vascular closure
12
procedural technical
12
major vascular
12
vascular complications
12
manta
10

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!