Background: Percutaneous axillary artery access is increasingly used for large-bore access during interventional vascular and cardiac procedures. The aim of this study was to evaluate the safety and learning curve of percutaneous axillary artery access in patients undergoing complex endovascular aortic repair (fenestrated and branched endovascular aneurysm repair [FBEVAR]) requiring large-bore upper extremity access and to discuss best practices for technique and complication management.

Methods: One-hundred forty-six patients undergoing large-bore percutaneous axillary artery access during FBEVAR in a prospective, nonrandomized, Investigational Device Exemption study between September 2017 and January 2023 were analyzed. Ultrasound guidance and micropuncture were used to access the second portion of the axillary artery and 2 Perclose Proglide or Prostyle devices (Abbott Vascular) were predeployed before the insertion of the large-bore sheath. Completion angiography was performed in all patients to verify hemostatic closure. Axillary artery patency was also assessed on follow-up computed tomography angiography. Patient-related, procedural, and postoperative variables were collected and analyzed.

Results: One-hundred forty-five patients underwent successful percutaneous axillary artery access; 1 patient failed axillary access and alternative access was established. The left axillary artery was accessed in 115 patients (79%), and the right axillary artery was accessed in 30 patients (21%). The largest profile sheath was 14 F in 4 patients (2.8%), 12F in 133 patients (91.7%), and 8F in 8 patients (5.5%). Ten patients (6.9%) required covered stent placement (Viabahn, W. L. Gore & Associates) for failure to achieve hemostasis; there were no conversions to open surgical repair. Additional adverse events included transient upper extremity weakness in two patients (1.3%) and transient upper extremity paresthesias in two patients (1.3%). Three patients (2%) suffered postoperative strokes, including one unrelated hemorrhagic stroke and two possibly access-related embolic strokes. On follow-up, axillary artery patency was 100%. There was a trend toward decreased closure failure over time, with seven patients (10%) in the early cohort and three (4%) in the late cohort. There was a significant negative correlation between the cumulative complication rate and the cumulative experience.

Conclusions: Large-bore percutaneous axillary artery access provides safe upper extremity large-bore access during FBEVAR, achieving successful closure in >90% of patients with a low incidence of access-related complications. There was a trend toward better closure rates with increasing experience, suggesting a learning curve effect. Application of best practices including ultrasound guidance and angiography may ensure safe application of the technique of percutaneous large-bore axillary artery access.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2023.10.048DOI Listing

Publication Analysis

Top Keywords

axillary artery
48
artery access
28
percutaneous axillary
24
upper extremity
16
patients
15
axillary
13
access
13
learning curve
12
artery
12
safety learning
8

Similar Publications

Background: Arteriovenous fistulas (AVFs) in kidney transplant recipients are sometimes closed, either as a policy or due to complications. We collected data on the incidence of complications after AVF closure in a national cohort of transplanted patients.

Methods: Patients who received a kidney transplant between 2000 and 2015 and had a functional AVF that was later ligated or extirpated were included.

View Article and Find Full Text PDF

The complex of neurovascular structures surrounding the coracoid process, particularly the axillary artery, the thoracoacromial artery and theirs branches, plays a critical role in shoulder function. Detailed dissection was performed in 36 shoulders from 18 embalmed cadavers. The focus was on axillary artery branches in relation to the coracoid process and the documentation of anatomical variations in this area.

View Article and Find Full Text PDF

Surgical revascularisation in an adult with coarctation of the aorta.

BMJ Case Rep

January 2025

Department of Cardiothoracic and Vascular Surgery, Kasturba Medical College, Manipal Academy of Higher Education, Mangalore, Karnataka, India

One of the most common congenital cardiac anomalies is It accounts for 4%-6% of all congenital heart defects. A CoA case surviving into adulthood may result in hypertension, weak femoral pulse, limb and bowel ischaemia and heart failure. A man in his early 20s presented with severe lower limb and abdominal pain with long-standing hypertension, refractory to antihypertensives.

View Article and Find Full Text PDF

The use of temporary left ventricular assist devices (tLVADs) for patients suffering from cardiogenic shock (CS) is becoming more common. This study examines the indications and outcomes of microaxial flow pumps (Impella, Abiomed Inc., Danvers, MA, USA) when cannulated through the axillary artery in patients with severe CS, with a particular focus on acute phase reactions and hemolytic responses.

View Article and Find Full Text PDF

Case report: Detecting giant cell arteritis in [Ga]Ga-DOTA-Siglec-9-PET/CT.

Front Immunol

January 2025

Department of Rheumatology and Clinical Immunology, Clinic of Internal Medicine III, University Hospital Bonn, Bonn, Germany.

Objectives: This study aimed to evaluate the diagnostic utility of [Ga]Ga-DOTA-Siglec-9 positron emission tomography-computed tomography (PET/CT) in assessing disease activity in a patient experiencing a relapse of giant cell arteritis (GCA).

Case Presentation: A 90-year-old male patient with GCA, diagnosed in 2018, was enrolled. Demographic data, disease history, and laboratory parameters, including soluble VAP-1 (sVAP-1) levels, were recorded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!