Accuracy of a novel modified single computed tomography scanning method for assisting dental implant placement: a retrospective observational study.

Int J Implant Dent

Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-Cho, Okayama, 700-8525, Japan.

Published: November 2023

Purpose: The aim of this study is to compare dental implant placement accuracy of three surgical guide fabrication methods: single (SCT) and double computed tomography (DCT), and a newly developed modified SCT (MSCT) scan method.

Methods: A total of 183 cases (183 surgical guides, and 485 implants) of static-guide-assisted implant placement surgery using the SCT, DCT, or MSCT methods in a dental clinic were included in the study. Three-dimensional (3D) deviations (mm) at the entry and tip of the implant body between preoperative simulation and actual placement were measured as surrogate endpoints of implant placement accuracy. The following survey details were collected from medical records and CT data: sex, age at implant placement surgery, surgical guide fabrication method, number of remaining teeth, implant length, implant location, alveolar bone quality, and bone surface inclination at implant placement site in preoperative simulation, etc. Risk factors for reducing implant placement accuracy were investigated using generalized estimating equations.

Results: The SCT and DCT methods (odds ratios [ORs] vs. MSCT method: 1.438, 1.178, respectively), posterior location (OR: 1.114), bone surface buccolingual inclination (OR: 0.997), and age at implant placement surgery (OR: 0.995) were significant risk factors for larger 3D deviation at the entry; the SCT (OR: 1.361) and DCT methods (OR: 1.418), posterior location (OR: 1.190), implant length (OR: 1.051), and age at implant placement surgery (OR: 0.995) were significant risk factors for larger 3D deviation at the tip of the implant body.

Conclusions: Implant placement accuracy was better using the MSCT method compared to the SCT and DCT methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10622383PMC
http://dx.doi.org/10.1186/s40729-023-00509-8DOI Listing

Publication Analysis

Top Keywords

implant placement
40
placement accuracy
16
placement surgery
16
implant
15
sct dct
12
age implant
12
risk factors
12
dct methods
12
placement
11
computed tomography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!