We aimed developing and experimentally validating methods for 3D scale-selective polarimetry of multiply scattered fields in diffuse myocardium layers for mechanical myocardial injury prescription histological differential diagnostics. We used the synthesis of diffuse object field polarization-interference registration and polarization-inhomogeneous field digital holographic reconstruction and layer-by-layer complex amplitudes distributions The method for selection single and diffuse object field multiply scattered components polarization maps is proposed. The conditions for eliminating the distorting influence of a depolarized background high level are found. On the basis of еру object field single scattered component polarization maps a large-scale selective wavelet analysis the criteria (markers) for mechanical myocardial injury different prescription diagnosis was determinate. Excellent accuracy mechanical injury myocardium necrotic changes with different duration using polarization-interference wavelet differentiation were achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbio.202300372DOI Listing

Publication Analysis

Top Keywords

object field
12
multiply scattered
8
mechanical myocardial
8
myocardial injury
8
injury prescription
8
diffuse object
8
polarization maps
8
digital polarization-holographic
4
polarization-holographic wavelet
4
wavelet histology
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!