Objective: To investigate the effects of previous occupational noise exposure in older adults with hearing loss on (1) audiometric configuration and acoustic reflex (AR) thresholds and (2) self-reported hearing abilities and hearing aid (HA) effectiveness.
Design: A prospective observational study.
Study Sample: The study included 1176 adults (≥60 years) with bilateral sensorineural hearing loss. Pure-tone audiometry, AR thresholds, and responses to the abbreviated version of the Speech, Spatial, and Qualities of Hearing Scale (SSQ12) and the International Outcome Inventory for Hearing Aids (IOI-HA) questionnaire were obtained, along with information about previous occupational noise exposure.
Results: Greater occupational noise exposure was associated with a higher prevalence of steeply sloping audiograms in men and women and a 0.32 (95% CI: -0.57; -0.06) scale points lower mean SSQ12 total score among noise-exposed men. AR thresholds did not show a significant relation to noise-exposure status, but hearing thresholds at a given frequency were related to elevated AR thresholds at the same frequency.
Conclusions: A noise exposure history is linked to steeper audiograms in older adults with hearing loss as well as to poorer self-reported hearing abilities in noise-exposed men. More attention to older adults with previous noise exposure is warranted in hearing rehabilitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/14992027.2023.2272558 | DOI Listing |
J Clin Med
December 2024
Department of Otorhinolaryngology, Head and Neck Surgery, Bhaarath Medical College, Chennai 600073, Tamil Nadu, India.
The misuse of personalized listening devices (PLDs) resulting in noise-induced hearing loss (NIHL) has become a public health concern, especially among youths, including medical students. The occupational use of PLDs that produce high-intensity sounds amplifies the danger of cochlear deterioration and high-frequency NIHL especially when used in noisy environments. This study aims to evaluate the incidence and trends of NIHL among medical students using PLDs.
View Article and Find Full Text PDFInt Arch Occup Environ Health
January 2025
Department of Emergency, The First Hospital of China Medical University, No. 155, Nanjing North Street, Heping District, Shenyang, 11001, China.
Purpose: This study examines the link between high occupational noise exposure and atrial fibrillation (AF), given the limited existing evidence.
Methods: We conducted a cross-sectional study among participants from a large heavy industry enterprise in China. High noise exposure was defined as an equivalent A-weighted sound level (LAeq, 8 h) of ≥ 80 dB(A) during an 8 h workday.
Eur Radiol
January 2025
Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China.
Objectives: To evaluate the image quality and lung nodule detectability of ultralow-dose CT (ULDCT) with adaptive statistical iterative reconstruction-V (ASiR-V) post-processed using a deep learning image reconstruction (DLIR)-based image domain compared to low-dose CT (LDCT) and ULDCT without DLIR.
Materials And Methods: A total of 210 patients undergoing lung cancer screening underwent LDCT (mean ± SD, 0.81 ± 0.
eNeuro
January 2025
Hearing Technology @ WAVES, Department of Information Technology, Ghent University, Technologiepark 216, 9052 Zwijnaarde, Belgium
Speech intelligibility declines with age and sensorineural hearing damage (SNHL). However, it remains unclear whether cochlear synaptopathy (CS), a recently discovered form of SNHL, significantly contributes to this issue. CS refers to damaged auditory-nerve synapses that innervate the inner hair cells and there is currently no go-to diagnostic test available.
View Article and Find Full Text PDFeNeuro
January 2025
Research Group for Brain and Cognitive Science, Shahid Beheshti Medical University, Tehran, Iran.
Visual information emerging from the extrafoveal locations is important for visual search, saccadic eye movement control, and spatial attention allocation. Our everyday sensory experience with visual object categories varies across different parts of the visual field which may result in location-contingent variations in visual object recognition. We used a body, animal body, and chair two-forced choice object category recognition task to investigate this possibility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!