Noise equivalent count density (NEC density ) is often used to evaluate the image quality of whole-body fluorodeoxyglucose tomography tests. However, this index is calculated using the patient volume, which is difficult to obtain at every facility. In this study, we proposed new image quality indices that can be evaluated at all facilities. In total, 94 patients were enrolled in the study. The correlations of patients' body weight and BMI with volume were examined. New image quality indices normalized by body weight and BMI were defined as NEC bw and NEC bmi , respectively. Correlations between NEC bw , NEC bmi , and NEC density were examined. Further, the correlations between these two new indices and visual scores were evaluated. Good correlations were observed between volume and body weight (r = 0.861, P  < 0.001) and between volume and BMI (r = 0.728, P  < 0.001). NEC bw and NEC bmi correlated well with NEC density (r = 0.954 for NEC bw and r = 0.897 for NEC bmi , P  < 0.001). These correlations improved when the examined bed positions were set to the same number. Additionally, the correlations of visual scores with NEC bw and NEC bmi were similar to those between the visual score and NEC density . Our investigation indicated that the newly proposed image quality metrics, NEC bw and NEC bmi , were easily calculated and as useful as NEC density for evaluating image quality when subjects had similar physiques.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0000000000001787DOI Listing

Publication Analysis

Top Keywords

image quality
16
body weight
12
nec density
8
quality indices
8
weight bmi
8
nec nec
8
nec bmi
8
nec
6
simpler image
4
quality
4

Similar Publications

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

Application of Diagnostic Imaging in Exotic Animal Gastroenterology.

Vet Clin North Am Exot Anim Pract

January 2025

Avian and Exotic Pet Service, UQ Veterinary Medical Centre, Building 8156, Main Drive, University of Qld, Gatton, Queensland 4343, Australia. Electronic address:

Imaging of an exotic animal with gastroenteric disease is often essential to make a diagnosis. The selection of a modality and its effective use needs careful consideration in each case. Obtaining a high-quality image and its interpretation are an acquired skill.

View Article and Find Full Text PDF

Emerging biomarkers in Gaucher disease.

Adv Clin Chem

January 2025

Center for Orphan Drug Research, Department of Experimental and Clinical Pharmacology, College of Pharmacy, University of Minnesota, Minneapolis, MN, United States. Electronic address:

Gaucher disease (GD) is a rare lysosomal disorder characterized by the accumulation of glycosphingolipids in macrophages resulting from glucocerebrosidase (GCase) deficiency. The accumulation of toxic substrates, which causes the hallmark symptoms of GD, is dependent on the extent of enzyme dysfunction. Accordingly, three distinct subtypes have been recognized, with type 1 GD (GD1) as the common and milder form, while types 2 (GD2) and 3 (GD3) are categorized as neuronopathic and severe.

View Article and Find Full Text PDF

This consensus on primary hyperparathyroidism, drawn up under the aegises of the French Society of Endocrinology (SFE), French Association of Endocrine Surgery (AFCE) and French Society of Nuclear Medicine (SFMN), provides an update on positive, etiological and differential diagnosis and treatment in primary hyperparathyroidism. These recommendations take account of recent increase in the prevalence of primary hyperparathyroidism, due to 1. more systematic routine measurement of blood calcium and improved quality of parathyroid hormone assays, 2.

View Article and Find Full Text PDF

Chapter 3: IMPACT OF PRIMARY HYPERPARATHYROIDISM.

Ann Endocrinol (Paris)

January 2025

Hospices Civils de Lyon, Groupement Hospitalier Est, Endocrinology Federation, Lyon, France.

At present, primary hyperparathyroidism is most often discovered in an asymptomatic patient, but can sometimes be revealed by a renal or bone complications. In all cases, a full work-up is recommended, with assessment of renal function (glomerular filtration rate), 24-hour calciuria, screening for risk factors for lithiasis, and renal and urinary tract imaging (ultrasound or CT scan) to look for stones or nephrocalcinosis. Bone densitometry, with measurements of the spine, femur and radius, is the recommended reference test for demineralization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!