Widening Access: Sterile Tourniquets for Surgery to the Distal Humerus.

Cureus

Trauma and Orthopaedics, Manchester Shoulder and Elbow Unit, Wythenshawe Hospital, Manchester University Hospitals NHS Foundation Trust, Manchester, GBR.

Published: September 2023

Purpose of the study The use of tourniquets during surgery of the distal humerus can improve visibility and reduce surgical time. However, the available operating field can be limited due to the size and placement of the tourniquet. This proof-of-concept study aimed to determine if sterile tourniquets can provide a wider surgical field compared to non-sterile tourniquets for procedures around the distal humerus. Methods Volunteers (n = 5) were positioned to simulate access to the distal humerus. The distance from the posterior corner of the acromion to the tip of the olecranon was measured. Participants were draped according to the standard protocol for the use of a non-sterile or sterile tourniquet for distal humerus and humeral shaft fractures. Two non-sterile pneumatic tourniquets (standard and narrow) and two sterile tourniquets (pneumatic and elastic exsanguination) were tested. The surgical field was measured from the sterile drape or tourniquet proximally to the tip of the olecranon. A one-way repeated measures ANOVA was conducted to examine the effect of each tourniquet on the surgical field. Results The sterile elastic exsanguination tourniquet had the largest available field with a mean of 24.4 cm (71% of arm available for incision after application), followed by the sterile pneumatic tourniquet of 20.0 cm (58%), narrow non-sterile pneumatic of 19.2 cm (55%), and standard non-sterile pneumatic of 17.0 cm (49%). Repeated measures ANOVA determined that mean surgical field length is statistically significant between tourniquet devices (F (1.729, 6.914) = 21.783, p = .001). The surgical field length was statistically significantly increased from a non-sterile standard tourniquet to a sterile elastic tourniquet (7.4 (95% CI, 2.9-11.9) cm, p = .008) but not the other two tourniquet devices tested. Conclusion The use of certain types of sterile tourniquets can provide a wider surgical field compared to non-sterile tourniquets for procedures around the distal humerus, specifically the sterile elastic exsanguination tourniquet providing a statistically significant mean gain of 7.4 cm from the non-sterile tourniquets. These findings suggest that the use of sterile tourniquets should be considered more frequently in surgery of the distal humerus, and a sterile exsanguinating tourniquet could be considered for midshaft humeral fractures, facilitating safer exposure of the radial nerve and reduced blood loss.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10613037PMC
http://dx.doi.org/10.7759/cureus.46148DOI Listing

Publication Analysis

Top Keywords

distal humerus
28
surgical field
24
sterile tourniquets
20
sterile
12
surgery distal
12
tourniquet
12
non-sterile tourniquets
12
non-sterile pneumatic
12
elastic exsanguination
12
sterile elastic
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!