Objectives: The study aimed to compare the trueness and precision of five intraoral scanners (Emerald S, iTero Element 5D, Medit i700, Primescan, and Trios 4) and two indirect digitization techniques for both teeth and soft tissues on fresh mandibular and maxillary cadaver jaws.

Methods: The maxilla and mandible of a fully dentate cadaver were scanned by the ATOS industrial scanner to create a master model. Then, the specimens were scanned eight times by each intraoral scanner (IOS). In addition, 8 polyvinylsiloxane (PVS) impressions were made and digitized with a Medit T710 desktop scanner. Stone models were then poured and again scanned with the desktop scanner. All IOS, PVS, and stone models were compared to the master model to calculate the mean absolute surface deviation for mandibular teeth, maxillary teeth, and palate.

Results: For mandibular teeth, the PVS trueness was only significantly better than the Medit i700 (p < 0.001) and Primescan (p < 0.05). In maxillary teeth, the PVS trueness was significantly better than all IOSs (p < 0.05-0.001); the stone trueness was significantly better than Emerald S (p < 0.01), Medit i700 (p < 0.001) and Primescan (p < 0.01). In the palate, PVS and stone trueness were significantly lower than the iTero Element 5D (p < 0.01) and Trios 4 (p < p < 0.01). Stone trueness was significantly lower than the Medit i700 (p < 0.05). The precision in the palate was significantly lower for PVS and stone than for Emerald S (p < 0.01, p < 0.05), iTero Element 5D (p < 0.01, p < 0.01), Primescan (p < 0.001, p < 0.001), and Trios 4 (p < 0.001, p < 0.01). Significant differences in trueness between the IOSs were observed only in the mandibular teeth. The Medit i700 performed worse than Emerald S (p < 0.01) and iTero Element 5D (p < 0.01). For mandibular teeth, the Medit i700 was significantly more precise than Primescan (p < 0.01) and the Emerald S (p < 0.05). The Trios 4 was significantly less precise than Emerald S (p < 0.05). The precision of Medit i700 was significantly worse than iTero Element 5D (p < 0.01) for maxillary teeth, as well as the Primescan (p < 0.01) and Trios 4 (p < 0.05) for the palate.

Conclusions: In general, indirectly digitized models from PVS impressions had higher trueness than IOS for maxillary teeth; precision between the two methods was similar. IOS was more accurate for palatal tissues. The differences in trueness and precision for mandibular teeth between the various techniques were negligible.

Clinical Significance: All investigated IOSs and indirect digitization could be used for complete arch scanning in mandibular and maxillary dentate arches. However, direct optical digitization is preferable for the palate due to the low accuracy of physical impression techniques for soft tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2023.104764DOI Listing

Publication Analysis

Top Keywords

trueness precision
8
medit i700
8
master model
8
scanner ios
8
desktop scanner
8
stone models
8
mandibular teeth
8
precision complete
4
complete arch
4
arch dentate
4

Similar Publications

Feasibility, trueness and precision of intraoral scanners in digitizing maxillectomy defects with exposed zygomatic implants in situ: An in vitro 3D comparative study.

J Dent

January 2025

Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland; Department of Conservative Dentistry and Orofacial Prosthodontics, Complutense University of Madrid, Madrid, Spain; Complutense University of Madrid, Ramon y Cajal Research Institute (IRYCIS). Madrid, Spain. Electronic address:

Objectives: To in-vitro evaluate the feasibility and accuracy (trueness and precision) of various intraoral scanners (IOS) to digitize maxillectomy defect models with exposed zygomatic implants in situ.

Material And Methods: Six partially edentulous and edentulous maxillectomy defect models with 2 zygomatic implants each were obtained. References scans were obatined by using a laboratory scanner (inEos X5; Dentsply Sirona).

View Article and Find Full Text PDF

This work provides a statistical analysis of four different approaches suggested in the literature for the estimation of an unknown concentration based on data collected using the standard addition method. These approaches are the conventional extrapolation approach, the interpolation approach, inverse regression, and the normalization approach. These methods are compared under the assumption that the measurement errors are normally distributed and homoscedastic.

View Article and Find Full Text PDF

Nutritional evaluation after copper cloud point extraction in spirulina (Arthrospira sp.) samples with determination by digital image colorimetry.

Food Chem

December 2024

Universidade Estadual do Sudoeste da Bahia, Campus de Jequié, Departamento de Ciências e Tecnologias, Rua José Moreira Sobrinho s/n, 45208-091 Jequié, Bahia, Brazil; Universidade Federal da Bahia, Instituto de Química, Campus da Federação/Ondina, Rua Barão de Geremoabo s/n, 40.170-115, Salvador, Bahia, Brazil. Electronic address:

This study presents the development of a procedure based on copper preconcentration at the cloud point of commercial spirulina dietary supplements, with determination by digital image colorimetry. A fractional factorial design 2 and Doehlert matrix were applied in the method optimization. The developed method presented 0.

View Article and Find Full Text PDF

Zeolites are a large family of minerals and the most studied is the naturally occurring clinoptilolite. They possess anti-inflammatory, antioxidant, and detoxifying properties which makes them valuable for medicinal use. Element analysis of zeolite's composition is necessary for its precise chemical characterization, and within this work development of a suspension method for the determination of manga nese, iron, and zinc by total reflection X-ray fluorescence spec-trometry (TXRF) was presented.

View Article and Find Full Text PDF

Dentistry is steadily evolving along the digital pathway at a constant and sure pace. Intraoral scanners (IOSs) started to enhance the precision and trueness of the restorations, making prosthodontics treatment more predictable. The objective of this study was to compare the trueness and internal fit of the printed provisional veneers for 60 preparations with three different types of finish lines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!