A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Outcomes Following Implantable Cardioverter-Defibrillator Insertion in Patients 80 Years of Age or Older: A Statewide Population Cohort Study. | LitMetric

Background: Patients ≥ 80 years of age are underrepresented in major implantable cardioverter-defibrillator (ICD) trials, and real-world data are lacking. In this study, we sought to assess ICD utilisation, outcomes, and their predictors, in an unselected statewide population including patients ≥ 80 years old.

Methods: We extracted details of ICDs implanted from 2009 to 2018 in New South Wales (NSW), Australia from the Centre for Health Record Linkage administrative data sets. Analysis was stratified into age groups of < 60 years, 60-79 years, and ≥ 80 years.

Results: A total of 9304 patients (mean age 66.1 ± 13.1 years; 12.1% ≥ 80 years) had de novo ICD placement at an average rate of 1163 ± 122 patients per annum, with more implants in men in all age groups. After adjusting for NSW population size by sex, age group, and calendar year, mean implantation rates were 5.5 ± 0.6, 63.2 ± 8.6, and 52.7 ± 10.8 per 100,000 persons per annum in patients aged < 60 years, 60-79 years, and ≥ 80 years, respectively. In-hospital mortality was 0.4% and did not differ among age groups. However, 1-year mortality was 2.1%, 5.9%, and 10.7%, in those < 60 years, 60-79 years, and ≥ 80 years of age, respectively (P < 0.001), with hazard ratios for those aged ≥ 80 years of 4.3 (95% confidence interval [CI] 3.1-6.0) and those aged 60-79 years of 2.6 (95% CI 1.9-3.5) relative to those aged < 60 years (both P < 0.001) after adjusting for ICD indications, sex, implantation year, referral source, and comorbidities. In those aged ≥ 80 years, age > 83 years, congestive cardiac failure, chronic renal failure, neurodegenerative disease, and a higher Charlson comorbidity index score were each independent predictors of 1-year mortality.

Conclusions: ICD use in patients aged ≥ 80 years and 60-79 years was 10-fold that in patients aged < 60 years, and perioperative outcomes were good in all ages, but there was substantially increased 1-year mortality in those aged ≥ 80 years. Careful selection based on age and comorbidity may further reduce 1-year mortality in patients ≥ 80 years old receiving ICDs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2023.10.019DOI Listing

Publication Analysis

Top Keywords

≥ years
40
years
23
60-79 years
20
years age
16
years 60-79
16
aged ≥
16
patients ≥
12
age groups
12
years ≥
12
patients aged
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!