A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Wrist-Worn Sensor Validation for Heart Rate Variability and Electrodermal Activity Detection in a Stressful Driving Environment. | LitMetric

Wearable sensors are widely used to gather psychophysiological data in the laboratory and real-world applications. However, the accuracy of these devices should be carefully assessed. The study focused on testing the accuracy of the Empatica 4 (E4) wristband for the detection of heart rate variability (HRV) and electrodermal activity (EDA) metrics in stress-inducing conditions and growing-risk driving scenarios. Fourteen healthy subjects were recruited for the experimental campaign, where HRV and EDA were recorded over six experimental conditions (Baseline, Video Clip, Scream, No-Risk Driving, Low-Risk Driving, and High-Risk Driving) and by means of two measurement systems: the E4 device and a gold standard system. The overall quality of the E4 data was investigated; agreement and reliability were assessed by performing a Bland-Altman analysis and by computing the Spearman's correlation coefficient. HRV time-domain parameters reported high reliability levels in Baseline (r > 0.72), Video Clip (r > 0.71), and No-Risk Driving (r > 0.67), while HRV frequency domain parameters were sufficient in Baseline (r > 0.58), Video Clip (r > 0.59), No-Risk (r > 0.51), and Low-Risk Driving (r > 0.52). As for the EDA parameters, no correlation was found. Further studies could enhance the HRV and EDA quality through further optimizations of the acquisition protocol and improvement of the processing algorithms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10611310PMC
http://dx.doi.org/10.3390/s23208423DOI Listing

Publication Analysis

Top Keywords

video clip
12
heart rate
8
rate variability
8
electrodermal activity
8
hrv eda
8
no-risk driving
8
low-risk driving
8
driving
7
hrv
5
wrist-worn sensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!