The fire performance of epoxy and carbon-fiber-reinforced polymer (CFRP) composites with and without fire retardants (FR) (i.e., ammonium polyphosphate (APP), aluminum trihydroxide (ATH), melamine (MEL), expandable graphite (EG)) was investigated. A design of experiment (DoE) approach was applied to study the single- and multifactorial effects of FR. The fire performance of epoxy and CFRP was evaluated by limiting the oxygen index (LOI) and heat release, which were obtained by limiting the oxygen index test and cone calorimetry. It was found that mixtures of 70 wt.-% epoxy, 24.6 wt.-% of APP, and 5.4 wt.-% MEL resulted in the highest LOI level of 45 within tested groups for epoxy resin and also for CFRP specimens (LOI level of 39). This mixture also resulted in the lowest average heat release rate (HRR) of 104 kW·m and a spec. total heat release (THR) of 1.14 MJ·m·g, indicating the importance of balancing spumific and charring agents in intumescent systems and synergy thereof.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10610378 | PMC |
http://dx.doi.org/10.3390/polym15204096 | DOI Listing |
Cureus
December 2024
Department of Emergency Medicine, Johns Hopkins University School of Medicine, Baltimore, USA.
Objective Prior studies have described the patterns of emergency medical service (EMS) activations in national parks in the United States. However, little data exists regarding EMS activations in local and regional outdoor recreational locations. We performed a retrospective analysis of EMS activations originating from parks and recreational areas in suburban Howard County, Maryland, to characterize those activations determined to be time-critical emergencies.
View Article and Find Full Text PDFACS Appl Bio Mater
January 2025
Department of Mechanical Engineering, Changwon National University, Changwon, Gyeongsangnam 51140, South Korea.
The current work presents the flame-retardant performance of hybrid polypropylene composites, reinforced with specific short woven flax fabrics (SWFs), short basalt fibers (BFs), and rice husk powder (RHP), using polypropylene grafted maleic anhydride (MAPP) as the coupling agent. Horizontal burning test (HBT), microcalorimeter test (MCT), and cone calorimeter test (CCT) were conducted on these composites. The formulations used were 25% SWF/PP, 25% SWF/20% BF/PP, and 25% SWF/20% BF/PP with 6% RHP and 25% SWF/20% BF/PP with varying RHP contents (6, 12, and 18%) in combination with 6% MAPP.
View Article and Find Full Text PDFPrehosp Emerg Care
January 2025
EMS Bridge, Public Health Institute, Oakland, CA.
Objectives: Opioid use disorder (OUD) remains a common cause of overdose and mortality in the United States. Emergency medical services (EMS) clinicians often interact with patients with OUD, including during or shortly after an overdose. The aim of this study was to describe the characteristics and outcomes of patients receiving prehospital buprenorphine for the treatment of opioid withdrawal in an urban EMS system.
View Article and Find Full Text PDFPrehosp Emerg Care
January 2025
Department of Emergency Medicine, College of Medicine, The University of Arizona, Tucson, AZ.
Objectives: Buprenorphine is becoming a key component of prehospital management of opioid use disorder (OUD). It is unclear how many prehospital patients might be eligible for buprenorphine induction, as traditional induction requires that patients first have some degree of opioid withdrawal. The primary aim of this study was to quantify how many patients developed precipitated withdrawal after receiving prehospital naloxone for suspected overdose, as they could be candidates for prehospital buprenorphine.
View Article and Find Full Text PDFBackground: Members of the Fire Department of New York (FDNY) who responded to the World Trade Center (WTC) attacks that occurred on 9/11/2001 were exposed to severe trauma. The present study screened for cognitive impairment in a prospective cohort study of FDNY fire fighters and emergency personnel who reside in the greater NYC metropolitan area.
Method: A large sample (n = 338) of FDNY personnel who were exposed to the WTC attacks were recruited to complete a large battery of neuropsychiatric and psychological tests.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!