The design, characterization, and analytical application of a green optical sensor for the selective determination of Fe(II) ions is proposed. The sensor is based on the immobilization of the chromogenic reagent picolinaldehyde salicyloylhydrazone (SHPA) within a polymer inclusion membrane. To reduce solvent usage, the reagent was synthesized using a green mechanochemical procedure. The components for sensor preparation were optimized with a sequential simplex method and the optimal composition was found to be 0.59 g cellulose triacetate (base polymer), 0.04 g SHPA (chemosensor reagent), 4.9 mL dibutyl phthalate (plasticizer), and 38 mL dichloromethane (solvent). The conditions of iron analysis were also optimized resulting in pH 6 for aqueous solution, 90 min exposure time and 10 min short-term stability. The optical sensor showed a linear range from the limit of detection (0.48 µmol L) to 54 µmol L Fe(II). The precision of the method was found to be 1.44% and 1.19% for 17.9 and 45 µmol L Fe(II), respectively. The characteristics of the sensor allowed the design of a Fe(II)/Fe(III) speciation scheme. The methodology was successfully applied to the determination of iron in food preservatives, food additives, and dietary supplement. Additionally, the Fe speciation scheme was successfully applied to an agricultural fertilizer.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10610280 | PMC |
http://dx.doi.org/10.3390/polym15204082 | DOI Listing |
Anal Methods
January 2025
Department of Chemistry, Birla Institute of Technology and Science Pilani, Hyderabad 500078, India.
In this work, we have explored the metal ion sensing properties of two bisbenzimidazole-based fluorescent probes, that differ in their conformational flexibility, in an aqueous medium. The compound with a flexible methyl spacer (1) experienced blue shifts in its absorption and emission maxima (along with a turn-off response) upon the addition of Hg ions. On the contrary, the compound with a relatively rigid structure (2) showed red shifts in both its absorption and emission maxima (along with a turn-off response) when treated with Hg under similar conditions.
View Article and Find Full Text PDFNanomicro Lett
January 2025
Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry, Beihang University, Beijing, 100191, People's Republic of China.
The proliferation of wearable biodevices has boosted the development of soft, innovative, and multifunctional materials for human health monitoring. The integration of wearable sensors with intelligent systems is an overwhelming tendency, providing powerful tools for remote health monitoring and personal health management. Among many candidates, two-dimensional (2D) materials stand out due to several exotic mechanical, electrical, optical, and chemical properties that can be efficiently integrated into atomic-thin films.
View Article and Find Full Text PDFJ Fluoresc
January 2025
School of Chemistry & Environmental Engineering, Jilin Provincial International Joint Research Center of Photo-Functional Materials and Chemistry, Changchun University of Science and Technology, Changchun, 130022, China.
In this work, a new fluorescent sensor for detecting Cu was developed based on the Rhodamine derivative. It displayed strong fluorescence enhancement upon the addition of Cu, and other common metal ions do not significantly affect the optical properties of the sensor. This optical signal change caused solely by Cu is due to the opening of the lactone amide spiro ring structure, resulting in fluorescence emission.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Interdisciplinary Material Science Program, Vanderbilt University, Nashville, Tennessee 37235, United States.
Porous silicon (PSi) thin films on silicon substrates have been extensively investigated in the context of biosensing applications, particularly for achieving label-free optical detection of a wide range of analytes. However, mass transport challenges have made it difficult for these biosensors to achieve rapid response times and low detection limits. In this work, we introduce an approach for improving the efficiency of molecule transport in PSi by using open-ended PSi membranes atop paper substrates in a flow-through sensor scheme.
View Article and Find Full Text PDFNanoscale
January 2025
AIT Austrian Institute of Technology, Molecular Diagnostics, 1210 Vienna, Austria.
Metal nanoparticles are established tools for biomedical applications due to their unique optical properties, primarily attributed to localized surface plasmon resonances. They show distinct optical characteristics, such as high extinction cross-sections and resonances at specific wavelengths, which are tunable across the wavelength spectrum by modifying the nanoparticle geometry. These attributes make metal nanoparticles highly valuable for sensing and imaging in biology and medicine.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!