As the power electronics landscape evolves, pushing for greater vertical integration, capillary underfilling is considered a versatile encapsulation technique suited for iterative development cycles of innovative integration concepts. Since a defect-free application is critical, this study proposes a capillary two-phase flow simulation, predicting both the flow pattern and velocity with remarkable precision and efficiency. In a preliminary performance evaluation, Volume of Fluid (VOF) outperforms the Level-Set method in terms of accuracy and computation time. Strategies like HRIC blending, artificial viscosity, and implicit Multi-Stepping prove effective in optimizing the numerical VOF scheme. Digital mapping using physical experiments and virtual simulations validates transient flow predictions, achieving excellent agreement with deviations as low as 1.48-3.34%. The accuracy of flow predictions is thereby greatly influenced by non-Newtonian viscosity characteristics in the low shear range and time-dependent contact angle variations. The study further explores flow manipulation concepts, focusing on local flow speed adjustment, gap segmentation, and the use of arcuate shapes to influence interface confluence near the chip. Experimental validation corroborates the effectiveness of each design intervention. In conclusion, this research highlights the potential of predictive engineering to develop flow-optimized package designs that enhance reliability while supporting high manufacturing yields.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609424PMC
http://dx.doi.org/10.3390/mi14101885DOI Listing

Publication Analysis

Top Keywords

flow simulation
8
flow predictions
8
flow
7
capillary underfill
4
underfill flow
4
simulation design
4
design tool
4
tool flow-optimized
4
flow-optimized encapsulation
4
encapsulation heterogenous
4

Similar Publications

Culturing living cells in three-dimensional environments increases the biological relevance of laboratory experiments, but requires solutes to overcome a diffusion barrier to reach the centre of cellular constructs. We present a theoretical and numerical investigation that brings a mechanistic understanding of how microfluidic culture conditions, including chamber size, inlet fluid velocity and spatial confinement, affect solute distribution within three-dimensional cellular constructs. Contact with the chamber substrate reduces the maximally achievable construct radius by 15%.

View Article and Find Full Text PDF

Experimental measurements of particle deposition in the human nasal airway.

Int J Pharm

January 2025

School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia.

Intranasal drug delivery is a promising non-invasive method for administering both local and systemic medications. While previous studies have extensively investigated the effects of particle size, airflow dynamics, and deposition locations on deposition efficiency, they have not focused on the thickness of deposited particles, which can significantly affect drug dissolution, absorption and therapeutic efficacy. This study investigates the deposition patterns of dry powder particles within the nasal airway, specifically examining how factors such as flow rates, particle size, and particle cohesiveness influence deposition patterns and their thickness.

View Article and Find Full Text PDF

Hemodynamic processes from the portal vein(PV) to the inferior vena cava(IVC) were mimicked for three patients with portal hypertension(PH) and the effects of stent parameters on the outcomes of transjugular intrahepatic portosystemic shunt(TIPS) were investigated through computational fluid dynamics(CFD). The liver region was simulated with porous media model and the spatial distributions of superior mesenteric vein(SMV) and splenic vein(SV) blood were solved through the Eulerian multiphase model. The present method is able to simulate the PH flow and predict the PV pressure, the stent shunt rate and the SMV blood proportion after TIPS treatment.

View Article and Find Full Text PDF

: The utilization of intra-aortic balloon pump (IABP) and Impella has been suggested as means of left ventricular unloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) patients. This study aimed to assess the local hemodynamic alterations in VA-ECMO patients through simulation analyses. : In this study, a 0D-3D multiscale model was developed, wherein resistance conditions were employed to define the flow-pressure relationship.

View Article and Find Full Text PDF

Understanding the ultrafast vibrational relaxation following photoexcitation of molecules in a condensed phase is essential to predict the outcome and improve the efficiency of photoinduced molecular processes. Here, the vibrational decoherence and energy relaxation of a binuclear complex, [Pt2(P2O5H2)4]4- (PtPOP), upon electronic excitation in liquid water and acetonitrile are investigated through direct adiabatic dynamics simulations. A quantum mechanics/molecular mechanics (QM/MM) scheme is used where the excited state of the complex is modeled with orbital-optimized density functional calculations while solvent molecules are described using potential energy functions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!