The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a new technology for the management of ICD patients. But what is the patients' perspective? Previous studies on the transvenous ICD (TV-ICD) showed that device implantation is related not only to anxiety and depression because of the fear of ICD shocks, but also to many biopsychosocial factors like body image changes, perceived reduction of socialization and limitation in professional and sports activities. Anxiety and distress are more evident in younger women because of aesthetic reasons. The scar size and the position of the S-ICD can help these patients and positively influence their social relationships. Moreover, the position of the S-ICD reduces possible complications from catheters due to stress injury and can improve patients' professional life by avoiding some work activity limitations. An S-ICD can be also a good option for athletes in avoiding subclavian crash and reducing inappropriate shocks. However, some questions remain unsolved because an S-ICD is not suitable for patients with indications for pacing, cardiac resynchronization therapy or anti-tachycardia pacing. In conclusion, the use of an S-ICD can assist physicians in reducing the negative impact of implantation on the well-being of some groups of patients by helping them to avoid depression and anxiety as well as improving their noncompliance with their medical treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10607293PMC
http://dx.doi.org/10.3390/jcm12206675DOI Listing

Publication Analysis

Top Keywords

subcutaneous implantable
8
implantable cardioverter-defibrillator
8
position s-icd
8
s-icd
6
cardioverter-defibrillator patient
4
patient perspective
4
perspective subcutaneous
4
cardioverter-defibrillator s-icd
4
s-icd technology
4
technology management
4

Similar Publications

The Masquelet technique that combines a foreign body reaction (FBR)-induced vascularized tissue membrane with staged bone grafting for reconstruction of segmental bone defect has gained wide attention in Orthopedic surgery. The success of Masquelet hinges on its ability to promote formation of a "periosteum-like" FBR-induced membrane at the bone defect site. Inspired by Masquelet's technique, here a novel approach is devised to create periosteum mimetics from decellularized extracellular matrix (dECM), engineered in vivo through FBR, for reconstruction of segmental bone defects.

View Article and Find Full Text PDF

Producing oral soft tissues using tissue engineering could compensate for the disadvantages of autologous grafts (limited availability and increased patient morbidity) and currently available substitutes (shrinkage). However, there is a lack of in vitro-engineered oral tissues due to the difficulty of obtaining stable pre-vessels that connect to the host and enable graft success. The main objective was to assess the connection of pre-vascularised 3D-bioprinted gingival substitutes to the host vasculature when subcutaneously implanted in immunodeficient mice.

View Article and Find Full Text PDF

This study investigates the mechanical properties as well as and cyto- and biocompatibility of collagen membranes cross-linked with glutaraldehyde (GA), proanthocyanidins (PC), hexamethylendiisocyanate (HMDI) and 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide (EC/NHS). A non-crosslinked membrane was used as reference control (RF). The initial cytotoxic analyses revealed that the PC, EC, and HMDI crosslinked membranes were cytocompatible, while the GA crosslinked membrane was cytotoxic and thus selected as positive control in the further study.

View Article and Find Full Text PDF

A phase-transited lysozyme coating doped with strontium on titanium surface for bone repairing via enhanced osteogenesis and immunomodulatory.

Front Cell Dev Biol

January 2025

Hunan Cancer Hospital, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University, Changsha, China.

Introduction: Titanium is currently recognized as an excellent orthopedic implant material, but it often leads to poor osseointegration of the implant, and is prone to aseptic loosening leading to implant failure. Therefore, biofunctionalization of titanium surfaces is needed to enhance their osseointegration and immunomodulation properties to reduce the risk of implant loosening. We concluded that the utilization of PTL-Sr is a direct and effective method for the fabrication of multifunctional implants.

View Article and Find Full Text PDF

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an alternative to traditional ICDs. The PRAETORIAN score, based on chest radiographs, has been validated to predict the probability of successful S-ICD defibrillation testing by assessing factors like fat thickness between the coil and sternum and generator placement.

Objective: This study evaluated the correlation between the PRAETORIAN score and clinical characteristics, as well as implantation variables.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!