Introduction: The STEMI-DTU pilot study tested the early safety and practical feasibility of left ventricular (LV) unloading with a trans-valvular pump before reperfusion. In the intent-to-treat cohort, no difference was observed for microvascular obstruction (MVO) or infarct size (IS) normalized to either the area at risk (AAR) at 3-5 days or total LV mass (TLVM) at 3-5 days We now report a per protocol analysis of the STEMI-DTU pilot study.
Methods: In STEMI-DTU STUDY 50 adult patients (25 in each arm) with anterior STEMI [sum of precordial ST-segment elevation (ΣSTE) ≥4 mm] requiring primary percutaneous coronary intervention (PCI) were enrolled. Only patients who met all inclusion and exclusion criteria were included in this analysis. Cardiac magnetic resonance (CMR) imaging 3-5 days after PCI quantified IS/AAR and IS/TLVM and MVO. Group differences were assessed using Student's t-tests and linear regression (SAS Version-9.4).
Results: Of the 50 patients enrolled, 2 died before CMR imaging. Of the remaining 48 patients those without CMR at 3-5 days (n = 8), without PCI of a culprit left anterior descending artery lesion (n = 2), with OHCA (n = 1) and with ΣSTE < 4 mm (n = 5) were removed from this analysis leaving 32/50 (64 %) patients meeting all inclusion and exclusion criteria (U-IR, n = 15; U-DR, n = 17) as per protocol. Despite longer symptom-to-balloon times in the U-DR arm (228 ± 80 vs 174 ± 59 min, p < 0.01), IS/AAR was significantly lower with 30 min of delay to reperfusion in the presence of active LV unloading (47 ± 16 % vs 60 ± 15 %, p = 0.02) and remained lower irrespective of the magnitude of precordial ΣSTE. MVO was not significantly different between groups (1.5 ± 2.8 % vs 3.5 ± 4.8 %, p = 0.15). Among patients who received LV unloading within 180 min of symptom onset, IS/AAR was significantly lower in the U-DR group.
Conclusion: In this per-protocol analysis of the STEMI-DTU pilot study we observed that LV unloading for 30 min before reperfusion significantly reduced IS/AAR compared to LV unloading and immediate reperfusion, whereas in the ITT cohort no difference was observed between groups. This observation supports the design of the STEMI-DTU pivotal trial and suggests that strict adherence to the study protocol can significantly influence the outcome.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.carrev.2023.09.009 | DOI Listing |
Am J Physiol Heart Circ Physiol
January 2025
Sport Medicine Unit, Careggi University Hospital, Via delle Oblate 4, 50134 Florence, Italy.
The study was designed to investigate the pattern of intraventricular Hemo-Dynamic Forces (HDF) and myocardial performance during exercise in Elite Cyclists (EC). Transthoracic stress echocardiography was performed on nineteen EC and thirteen age-matched sedentary controls (SC) at three incremental exercise intensities based on Heart Rate Reserve (HRR). Left Ventricular (LV) HDF were computed from echocardiography long-axis data sets using a novel technique based on endocardial boundary tracking, both in apex-base and latero-septal directions.
View Article and Find Full Text PDFThe authors propose a modified transcatheter aortic valve replacement technique wherein the removal of the guidewire and delivery catheter immediately after the valve implantation helps to not only shorten the procedure but also decrease complications induced by the guidewire and delivery catheter.
View Article and Find Full Text PDFJ Invasive Cardiol
January 2025
Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.
Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.
Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.
Curr Cardiol Rep
January 2025
Division of Cardiology, Department of Medicine, University of California San Francisco, 505 Parnassus Ave, M1180B, San Francisco, CA, 94143, USA.
Purpose Of Review: Cardiac conduction disease, a harbinger of pacemaker implantation, heart failure, and death, is commonly regarded as immutable. However, emerging research suggests it may be a target for upstream prevention strategies such as blood pressure management. This review summarizes recent evidence regarding blood pressure control and the development of conduction disease.
View Article and Find Full Text PDFEur Heart J
January 2025
School of Chemical Biology and Biotechnology, Peking University Shenzhen Graduate School, Shenzhen, 2199 Lishui Rd, Nanshan, Shenzhen, Guangdong Province 518055, China.
Background And Aims: Lackluster results from recently completed gene therapy clinical trials of VEGF-A delivered by viral vectors have heightened the need to develop alternative delivery strategies. This study aims to demonstrate the pre-clinical efficacy and safety of extracellular vesicles (EVs) loaded with VEGF-A mRNA for the treatment of ischaemic vascular disease.
Methods: After encapsulation of full-length VEGF-A mRNA into fibroblast-derived EVs via cellular nanoporation (CNP), collected VEGF-A EVs were delivered into mouse models of ischaemic injury.