A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Productivity and Thermal Performance Enhancements of Hollow Fiber Water Gap Membrane Distillation Modules Using Helical Fiber Configuration: 3D Computational Fluid Dynamics Modeling. | LitMetric

Although hollow fiber water gap membrane distillation (HF-WGMD) units offer certain advantages over other MD desalination systems, they still require enhancements in terms of distillate flux and productivity. Therefore, this work proposes a novel configuration by incorporating the helical turns of HF membranes within the water gap channel of the HF-WGMD modules. A fully coupled 3D CFD model is developed and validated to simulate the multifaceted energy conservations and diffusion mechanisms that are inherent to the transport phenomena in the proposed HF-WGMD module. Single and double helical HF membrane designs with different numbers of turns are compared to the reference modules of single and double straight HF membrane designs under various operational conditions. At a feed temperature of 70 °C, a noteworthy 11.4% enhancement in the distillate flux is observed when employing 20 helical turns, compared to the single straight HF membrane module. Furthermore, the specific productivity revealed a maximum enhancement of 46.2% when using 50 helical turns. The thermal performance of the proposed HF-WGMD module shows higher energy savings of up to 35% in specific thermal energy consumption for a one-stage module. Using three stages of single helical modules can increase the gain output ratio from 0.17 for the single stage to 0.37, which represents an increase of 117.6%. These findings indicate the high potential of the proposed approach in advancing the performance of HF-WGMD systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609078PMC
http://dx.doi.org/10.3390/membranes13100843DOI Listing

Publication Analysis

Top Keywords

water gap
12
helical turns
12
thermal performance
8
hollow fiber
8
fiber water
8
gap membrane
8
membrane distillation
8
distillate flux
8
proposed hf-wgmd
8
hf-wgmd module
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!