Zygomatic implants are used for the rehabilitation of the upper jaw of patients with severe and moderate bone atrophy. Possible post-surgical complications include soft tissue dehiscence, sinusitis, and prosthodontic fractures, and maintaining an accurate control is crucial. Additionally, zygomatic implants have a unique peri-implant anatomy, making traditional periodontal parameters unsuitable. The present paper aims to provide guidelines for the maintenance and interception of complications in patients rehabilitated with these kinds of implants. The proposed protocol includes: 1. intra/extraoral and temporo-mandibular joint examination; 2. soft tissue and transmucosal path observation with magnifiers; 3. peri-implant health indices and digital stimulation of tissues; 4. examination of prosthodontic devices; and 5. photographic recording. These steps facilitate the comprehensive evaluation and monitoring of clinical conditions of zygomatic-supported rehabilitations, including dehiscence and occlusal wear during follow-up appointments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10605483 | PMC |
http://dx.doi.org/10.3390/dj11100226 | DOI Listing |
Int J Surg Case Rep
January 2025
Department of Prosthodontics, RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al Khaimah, United Arab Emirates. Electronic address:
Introduction: Rehabilitation of patients with hemimaxillectomy presents a challenge. This case report describes the successful use of zygomatic Corticobasal® implant- supported reconstructed prosthesis.
Clinical Case Presentation: A 20-year-old female patient presented to the clinic following hemimaxillectomy with soft tissue approximation one year ago.
Objective: Evaluate the feasibility of the midface degloving approach (MDA) in total maxillectomy without orbital exenteration (TMWOE) and reconstruction for sino-nasal neoplasms.
Study Design: Retrospective case series.
Setting: Tertiary referral center.
Purpose: This retrospective study aimed to compare extended sinus lift and extramaxilla surgical protocols for restoring severely atrophic maxillae with zygomatic implants (ZIs) and evaluate their clinical effectiveness.
Materials And Methods: The study includes patients who were treated at a dental clinic in Italy from 2012 to 2022. These patients received fixed screw-retained complete dentures supported by either two or four zygomatic implants (ZIs).
J Oral Implantol
January 2025
PhD. Department of Periodontics, Saveetha Dental College, SIMATS, Saveetha University, Chennai, Tamil Nadu, India.
J Craniomaxillofac Surg
December 2024
School of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain; IDIBELL Institute, Barcelona, Spain.
Real-time surgical navigation systems (dynamic computer-aided surgery, d-CAIS) and static guided surgery (static computer-aided surgery, s-CAIS) have been shown to enhance the accuracy of zygomatic implant (ZI) placement. The objective of this systematic review was to evaluate and compare the accuracy and risk of complications associated with d-CAIS and s-CAIS in ZI placement. A systematic review of published studies involving more than 4 patients was conducted to assess and compare the accuracy of d-CAIS and s-CAIS in zygomatic implant placement.