A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Is ultraviolet light disinfection fit to be the future standard for the disinfection of flexible endoscopes without a working channel? | LitMetric

Objective: To investigate colony-forming unit (CFU) reduction on contaminated flexible endoscopes (FEs) without a working channel after UV-C light disinfection, compared to the current disinfection method with the endoscope washer disinfector (EWD).

Design, Setting And Participants: After pharyngolaryngoscopy, a manual pre-cleaning with tap water was performed. A culture was then collected by rolling the distal 8-10 cm of the FE over an Agar plate. The FE was disinfected using the D60 (60-s disinfection process with UV-C light) or the EWD (gold standard reprocessing process with water and chemicals). Another culture was then taken. After incubation, a CFU count was performed.

Results: A total of 200 FEs without a working channel were divided equally between the two disinfection groups. After clinical use and manual pre-cleaning, 84 of the 100 (84.0%) (UV-C light group) and 79 of the 100 (79.0%) (EWD) FEs were contaminated with at least 1 CFU. FEs that showed no contamination after use were excluded from further analysis. After disinfection with UV-C light, 72 (85.7%) FEs showed no contamination (i.e., 0 CFUs) versus 66 (83.5%) FEs after reprocessing with the EWD.

Conclusion: There is no difference in CFUs reduction on contaminated FEs without a working channel between UV-C light disinfection and the current gold standard, the EWD.

Download full-text PDF

Source
http://dx.doi.org/10.1111/coa.14119DOI Listing

Publication Analysis

Top Keywords

uv-c light
20
light disinfection
12
fes working
12
working channel
12
disinfection
8
flexible endoscopes
8
reduction contaminated
8
channel uv-c
8
manual pre-cleaning
8
gold standard
8