A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of annealing on the room temperature luminescence of coumarin 106 in PVA films. | LitMetric

Effect of annealing on the room temperature luminescence of coumarin 106 in PVA films.

Methods Appl Fluoresc

Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.

Published: November 2023

We studied the effect of annealing on the luminescence of Coumarin 106 (C106) in poly (vinyl alcohol) films (PVA films). The samples and reference polymer films were treated at temperatures between 100 °C and 150 °C (212 F and 302 F) for various times. After cooling and smoothing, the samples and references were measured at room temperature. We observed that the PVA polymer (reference films) changes its optical properties with annealing at higher temperatures, affecting the baselines in absorption and the backgrounds in emission measurements. This requires precise background subtractions and control of the signal-to-noise ratio. Whereas the fluorescence intensity of C106 in PVA films modestly decreases with annealing, the phosphorescence depends dramatically and progressively increases by many folds. The fluorescence quantum yields and lifetimes decrease with the annealing, which suggests an increase in the non-radiative processes in the singlet excited state S. The increase in the phosphorescence intensities results from increased intersystem crossing (ISC), which also decreases fluorescence. We also studied the effect of annealing on phosphorescence with the directly excited triplet state of C106. In this case, two processes are affected by annealing, S→Tabsorption and T→Sphosphorescence. The long-wavelength excitation (475 nm) avoids PVA polymer excitation. The phosphorescence lifetime decreases with annealing while the phosphorescence intensity increases. These changes suggest that the radiative rate of T→ Sincreases with annealing.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2050-6120/ad06dcDOI Listing

Publication Analysis

Top Keywords

pva films
12
annealing phosphorescence
12
annealing
9
room temperature
8
luminescence coumarin
8
coumarin 106
8
studied annealing
8
pva polymer
8
decreases annealing
8
films
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!