AI Article Synopsis

  • There is a lack of comparative data on the effectiveness of sirolimus-coated balloons (SCBs) versus paclitaxel-coated balloons (PCBs) in treating small vessel disease (SVD).
  • The study involved 121 patients and aimed to compare angiographic outcomes after 6 months of treatment with either SCB or PCB, with a focus on net lumen gain.
  • Results showed that SCBs did not meet the noninferiority criterion for net lumen gain compared to PCBs, demonstrating less improvement and higher rates of restenosis.

Article Abstract

Background: There are no data comparing sirolimus-coated balloons (SCBs [MagicTouch, Concept Medical]) to paclitaxel-coated balloons (PCBs [SeQuent Please Neo, B. Braun]) for the treatment of de novo small vessel disease (SVD).

Objectives: This study sought to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo SVD with a PCB or SCB.

Methods: This prospective, multicenter, noninferiority trial randomized 121 patients (129 SVD lesions) to treatment with an SCB or PCB, with balloon sizing determined using optical coherence tomography. The primary endpoint was noninferiority for the 6-month angiographic net lumen gain.

Results: Angiographic follow-up was completed in 109 (90.1%) patients in the per-protocol analysis. The mean ± SD angiographic net gains were 0.25 ± 0.40 mm with SCBs vs 0.48 ± 0.37 mm with PCBs, resulting in SCBs failing to meet the 0.30 mm criterion for noninferiority (P = 0.173), with an absolute difference of -0.23 mm (95% CI: -0.37 to -0.09) secondary to a smaller late loss (0.00 ± 0.32 mm vs 0.32 ± 0.47 mm; P < 0.001) and more frequent late lumen enlargement (53.7% vs 30.0%; OR: 2.60; 95% CI: 1.22-5.67; P = 0.014) with PCBs. Binary restenosis rates were 32.8% and 12.5% following treatment with SCBs and PCBs, respectively (OR: 3.41; 95% CI: 1.36-9.44; P = 0.012). The mean angiography-derived fractional flow ratio at follow-up was 0.86 ± 0.15 following treatment with SCBs and 0.91 ± 0.09 following PCBs (P = 0.026); a fractional flow ratio ≤0.80 occurred in 13 and 5 vessels after treatment with SCBs and PCBs, respectively.

Conclusions: The SCB MagicTouch failed to demonstrate noninferiority for angiographic net lumen gain at 6 months compared to the PCB SeQuent Please Neo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2023.09.026DOI Listing

Publication Analysis

Top Keywords

angiographic net
12
treatment scbs
12
comparing sirolimus-coated
8
treatment novo
8
net lumen
8
scbs pcbs
8
fractional flow
8
scbs
6
pcbs
6
treatment
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!