A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiation Exposure in Extracorporeal Life Support. | LitMetric

AI Article Synopsis

  • ECMO patients undergo multiple radiologic studies, leading to possibly excessive radiation exposure beyond recommended limits set by the ICRP.
  • In a study of 306 adult ECMO patients from 2016 to 2018, about 9.4% received over 50 mSv and 4.5% over 100 mSv of cumulative effective dose (CED).
  • The majority of radiation exposure was attributed to CT scans and interventional radiology procedures, highlighting the need for guidelines to reduce radiation exposure in these patients.

Article Abstract

Extracorporeal membrane oxygenation (ECMO) exposes patients to multiple radiologic studies. We hypothesized ECMO patients endure radiation exposure in excess of the International Commission of Radiological Protection (ICRP) recommendations of cumulative effective dose (CED, >20 mSv and 5-year cumulative limit of CED >100 mSv). We conducted a retrospective observational study in an academic medical center between January 2016 and December 2018 involving adult admissions (N = 306) on ECMO. Ionizing radiation was calculated from reference values to determine CED. Approximately 9.4% (N = 29) patients accrued CED >50 mSv and 4.5% (N = 14) accrued CED >100 mSv during ECMO. Over the entire hospitalization, 28% (N = 85) accrued >50 mSv and 14.7% (N = 45) accrued CED >100 mSv. Median CED during ECMO was 2.3 mSv (IQR, -0.82 to 8.1 mSv), and the entire hospitalization was 17.4 mSv (IQR, -4.5 to 56.6 mSv). Thirteen percent of the median CED accrued during hospitalization could be attributed to ECMO. Longer hospitalization was associated with a higher CED (50 days [IQR, -25 to 76 days] in CED >50 vs. 19 days [IQR, -10 to 32 days] in CED <50). Computer tomography (CT) scans and interventional radiology (IR) procedures contributed to 43.8% and 44.86%, respectively, of CED accrued on ECMO and 52.2% and 37.1% of CED accumulated during the whole hospitalization. Guidelines aimed at mitigating radiation exposure are urgently needed.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAT.0000000000002037DOI Listing

Publication Analysis

Top Keywords

ced >100
12
>100 msv
12
accrued ced
12
ced
11
msv
10
radiation exposure
8
ced >50
8
>50 msv
8
entire hospitalization
8
median ced
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!