Purpose: For aortic coarctation in adults endovascular repair is the treatment of choice with an acceptable safety profile. Aortic isthmus atresia is a related condition with a complete occlusion of the aorta not allowing catheterization across the isthmus. This technical note describes a recanalization of an aortic isthmus atresia using radiofrequency with an "electrified wire technique."

Technique: A guidewire was selectively denuded of PTFE (polytetrafluoroethylene) at the distal end and was placed through a catheter distal to the aortic isthmus atresia. The denuded end of the wire was clamped to an electrosurgery pencil. By pushing the wire toward a tulip-snare, which was placed as a target proximal of the occlusion via left trans-brachial access, and shortly activating of the electrosurgery pencil the electrified wire recanalized the occlusion and was snared and used to guide implantation of a balloon-expandable covered stent.

Conclusion: The electrified wire puncture technique can be used to recanalize adult aortic isthmus atresia after failed conventional attempts.

Clinical Impact: The electrified wire technique offers an off-the shelf option to modify standard guidewires for the use with radiofrequency to cross a complete aortic isthmus occlusion after failed conventional attempts. This new technique may be applied also in other situations like dissection flap fenestration, transcaval access and similar.

Download full-text PDF

Source
http://dx.doi.org/10.1177/15266028231206996DOI Listing

Publication Analysis

Top Keywords

aortic isthmus
24
isthmus atresia
20
electrified wire
12
recanalization aortic
8
"electrified wire
8
electrosurgery pencil
8
failed conventional
8
aortic
7
isthmus
7
wire
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!