The finite element method has often been used to assist analyzing local flaps in terms of deformation and stress measurements as it takes into account complex skin properties. We, herein, present an isotropic two-dimensional finite element skin model applied to the W-plasty method to demonstrate that the good outcomes of W-plasty should be attributed to the geometry itself, as it generates lower stresses. The skin was modeled as a two-dimensional (2D) planar geometry. The model was created and solved as a plane stress problem. The model was based on simulation of the loading and stitching of W-plasties of various angles. Each central triangular flap was segmented in nine triangular elements. The stitching was modeled with one suture at the top of each triangular flap with the center of the opposite corner. X- and Y-axis stresses and shearing stresses Txy in the elements involved in the broken stitching line, show lower stresses than the elements behind the stitching line. Interestingly, in the triangular flaps, the stresses were clearly lower than those of their neighboring areas. The maximum compressive stresses in the 2D model we used, correspond to the dog ears. We conclude that the effectiveness of W-plasty should be attributed not only to the scar orientation in relation to the relaxed tension skin lines but also to the special design of the triangular flaps used. This finding assists the general understanding of the method and should be taken into account by the clinician during flap designing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10593918PMC
http://dx.doi.org/10.1038/s41598-023-45400-zDOI Listing

Publication Analysis

Top Keywords

finite element
12
element method
8
w-plasty attributed
8
lower stresses
8
triangular flap
8
elements stitching
8
triangular flaps
8
stresses
6
triangular
5
biomechanical explanation
4

Similar Publications

Two-point contact is one of the fundamental problems of wheel-rail contact in switch area. The contact state and the distribution of forces are complex and essential points in wheel-rail relationship. Given the problem that the current dynamic wheel-rail contact state is challenging to detect, a theory to detect the two-point contact state of the wheel-rail in switch area using a discrete gauge column was presented and proved in the finite element model.

View Article and Find Full Text PDF

Understanding the mechanical properties of Rosa sterilis S.D. Shi is important for the design and improvement of related mechanical equipment for planting, picking, processing, and transporting Rosa sterilis S.

View Article and Find Full Text PDF

This study presents an advanced dynamic finite element (FE) model of multiple components of the breast to examine the biomechanical impact of different types of physical activities and activity intensity on the breast tissues. Using 4D scanning and motion capture technologies, dynamic data are collected during different activities. The accuracy of the FE model is verified based on relative mean absolute error (RMAE), and optimal material parameters are identified by using a validated stepwise grid search method.

View Article and Find Full Text PDF

The effect of bone relaxation on the simulated pull-off force of a cementless femoral knee implant.

J Biomech

January 2025

Radboudumc, Orthopaedic Research Lab, PO Box 9101, 6500 HB Nijmegen, the Netherlands.

Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty (TKA), emphasizing the importance of strong initial stability for long-term implant success. Pre-clinical evaluations are crucial for understanding implant fixation mechanics and improving implant designs. Finite element (FE) analysis models often use linear elastic bone material models, which do not accurately reflect bone's mechanical behavior.

View Article and Find Full Text PDF

Accurate operando measurement of AlGaN/GaN HEMTs channel temperature and optimization of thermal design.

Nanotechnology

January 2025

Electronic Sci.&Eng., Xi'an Jiaotong University, 28 Xianning West Road,Beilin District, Xi 'an, Shaanxi Province, China, Xi'an, 710049, CHINA.

The accurate estimation of the temperature distribution of the GaN based power devices and optimization of the device structure is of great significance to possibly solve the self-heating problem, which hinders the further enhancement of the device performances. We present here the operando temperature measurement with high spatial resolution using Raman spectroscopy of AlGaN/GaN high electron mobility transistors (HEMTs) with different device structures and explore the optimization of the device thermal design accordingly. The lateral and depth temperature distributions of the single-finger HEMT were characterized.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!