Completely leadless cardiac resynchronization therapy is feasible with the combination of Micra AV pacemaker (Medtronic Inc) and WiSE-CRT (EBR Inc) systems. Several reports have highlighted this combination in Europe. This case report presents a 1- year follow-up the first reported concomitant use of the leadless systems in the United States. ().

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10589444PMC
http://dx.doi.org/10.1016/j.jaccas.2023.102020DOI Listing

Publication Analysis

Top Keywords

completely leadless
8
leadless cardiac
8
cardiac resynchronization
8
resynchronization therapy
8
long-term outcome
4
outcome completely
4
therapy united states
4
united states completely
4
therapy feasible
4
feasible combination
4

Similar Publications

Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.

View Article and Find Full Text PDF

3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.

Eur Heart J Case Rep

January 2025

AL Qassimi Hospital, Emirates Health Services (EHS), Wasit Street-Al khazamiya, Sharjah 3500, United Arab Emirates.

Background: The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.

Case Summary: A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block.

View Article and Find Full Text PDF

A 21-year-old man, known case of the repaired congenital heart disease, developed complete atrioventricular block (AVB) one week after simultaneous bioprosthetic pulmonary and tricuspid valve replacement and atrial septal defect repair. Considering the persistence of the AVB, it was decided to implant a permanent pacemaker. After considering all available options and the issues related to the patient, it was decided to implant a leadless pacemaker (LLP).

View Article and Find Full Text PDF

A rare cardiac presentation of a lymphoma: case report.

Eur Heart J Case Rep

January 2025

Department of Cardiology, Klinik Floridsdorf, Brünnerstraße 68, Vienna 1210, Austria.

Background: Cardiac lymphoma is a rare disease that can present in various ways. Additionally, atypical clinical presentation makes the diagnosis even more challenging. The most common type of cardiac lymphoma is diffuse large B-cell lymphoma.

View Article and Find Full Text PDF

Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.