Background: Near-infrared autofluorescence imaging is an adjunct to parathyroid identification. As it does not show perfusion, it is important to study its impact during thyroidectomy by measuring quantifiable data on parathyroid detection rather than function. The aim of this study was to compare incidental parathyroidectomy rates in patients undergoing total thyroidectomy with or without near-infrared autofluorescence.
Methods: Retrospective study of patients who underwent total thyroidectomy between 2014 and 2022 at one center. Clinical parameters, including rates of incidental parathyroid tissue on pathology reports, were compared between near-infrared autofluorescence and non-near-infrared autofluorescence groups. Near-infrared autofluorescence was used to guide dissection (identification) and/or to confirm tissue as parathyroid (confirmation). Statistical analysis was done with Wilcoxon rank sum test and χ analysis.
Results: There were 300 patients in the near-infrared autofluorescence and 750 patients in the non-near-infrared autofluorescence group. The rate of incidental parathyroid tissue detection on final pathology was 13.3% (n = 40) in the near-infrared autofluorescence and 23.2% (n = 174) in the non-near-infrared autofluorescence group (P < .001). The rate of incidental parathyroid tissue detected on pathology with near-infrared autofluorescence decreased when used for identification and confirmation of parathyroid tissue (30.0% to 13.4%, P < .001), but not when used for confirmation only (19.6% to 18.5%, P = .89). Impact of near-infra red autofluorescence in decreasing the rate of incidental parathyroid tissue was more profound for early (38.5% to 17.1%) versus mid-late career surgeons (20% to 13%).
Conclusion: Our results suggest that the use of near-infrared autofluorescence may help decrease the rate of incidental parathyroid tissue detected on final pathology if used for both identification and confirmation of parathyroid glands during thyroidectomy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.surg.2023.05.047 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.
Fluorescence thermometry based on metal halide perovskites is increasingly becoming a hotspot due to its advantages of high detection sensitivity, noninvasiveness, and fast response time. However, it still presents certain technical challenges in practical applications, such as complex synthesis methods, the use of toxic solvents, and being currently mainly based on the visible/first near-infrared light with poor penetration and severe autofluorescence. In this study, we synthesize the second near-infrared (NIR-II) luminescent crystals based on Yb/Nd-doped zero-dimensional CsScCl·HO by a simple "dissolve-dry" method.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
Department of Chemistry, Laboratory of Advanced Materials, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433, China.
Optical imaging in the second near-infrared window (NIR-II, 1000-1700 nm) holds great promise for biomedical detection due to reduced tissue scattering and autofluorescence. However, the rational design of NIR-II probes with superior excitation wavelengths to balance the effects of tissue scattering and water absorption remains a great challenge. To address this issue, here we developed a series of Ho-sensitized lanthanide (Ln) nanocrystals (NaYF: Ho, Ln@NaYF) excited at 1143 nm, featuring tunable emissions ranging from 1000 to 2200 nm for bioimaging.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 1, Singapore, 117585, Singapore.
Strong background interference signals from normal tissues have significantly compromised the sensitive fluorescence imaging of early disease tissues with exogenous probes in vivo, particularly for sensitive fluorescence imaging of early liver disease due to the liver's significant uptake and accumulation of exogenous nanoprobes, coupled with high tissue autofluorescence and deep tissue depth. As a proof-of-concept study, we herein report a near-infrared-II (NIR-II, 1.0-1.
View Article and Find Full Text PDFAdv Funct Mater
October 2024
Department of Chemical and Biomolecular Engineering, University of California, Berkeley, CA 94720, USA.
Traditional deep fluorescence imaging has primarily focused on red-shifting imaging wavelengths into the near-infrared (NIR) windows or implementation of multi-photon excitation approaches. Here, we combine the advantages of NIR and multiphoton imaging by developing a dual-infrared two-photon microscope to enable high-resolution deep imaging in biological tissues. We first computationally identify that photon absorption, as opposed to scattering, is the primary contributor to signal attenuation.
View Article and Find Full Text PDFACS Appl Bio Mater
December 2024
State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing 100029, People's Republic of China.
Afterglow fluorescence imaging has been extensively assessed in ultrasensitive bioimaging. Since it eliminates the need for real-time excitation light and thereby circumvents the autofluorescence background of tissue, it holds tremendous potential in accurate biomedical imaging. However, current afterglow probes are rare and emit light only in the visible to near-infrared (NIR) range, which is inadequate for imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!