Evolution of Echocardiography-Derived Hemodynamic Force Parameters After Cardiac Resynchronization Therapy.

Am J Cardiol

Departments of Cardiology, Leiden University Medical Centre, Leiden, The Netherlands; Department of Cardiology, Turku Heart Center, University of Turku and Turku University Hospital, Turku, Finland. Electronic address:

Published: December 2023

Echocardiography-derived hemodynamic forces (HDF) allow calculation of intraventricular pressure gradients from routine transthoracic echocardiographic images. The evolution of HDF after cardiac resynchronization therapy (CRT) has not been investigated in large cohorts. The aim was to assess HDF in patients with heart failure implanted with CRT versus healthy controls. HDF were assessed before and 6 months after CRT. The following HDF parameters were calculated: (1) apical-basal strength, (2) lateral-septal strength, (3) the ratio of lateral-septal to apical-basal strength ratio, and (4) the force vector angle (1 and 2 representing the magnitude of HDF, 3 and 4 representing the orientation of HDF). In the propulsive phase of systole, the apical-basal impulse and the systolic force vector angle were measured. A total of 197 patients were included (age 64 ± 11 years, 62% male), with left ventricular ejection fraction ≤35%, QRS duration ≥130 ms and left bundle branch block. The magnitude of HDF was significantly lower and the orientation was significantly worse in patients with heart failure versus healthy controls. Immediately after CRT implantation, the apical-basal impulse and systolic force vector angle were significantly increased. Six months after CRT, improvement of apical-basal strength, lateral-septal to apical-basal strength ratio and the force vector angle occurred. When CRT was deactivated at 6 months, the increase in the magnitude of apical-basal HDF remained unchanged while the systolic force vector angle worsened significantly. In conclusion, HDF in CRT recipients reflect the acute effect of CRT and the effect of left ventricular reverse remodeling on intraventricular pressure gradients. Whether HDF analysis provides incremental value over established echocardiographic parameters, remains to be determined.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2023.09.098DOI Listing

Publication Analysis

Top Keywords

force vector
20
vector angle
20
apical-basal strength
16
strength ratio
12
systolic force
12
hdf
11
echocardiography-derived hemodynamic
8
cardiac resynchronization
8
resynchronization therapy
8
intraventricular pressure
8

Similar Publications

Water conveyance channels in cold and arid regions pass through several saline-alkali soil areas. Canal water leakage exacerbates the salt expansion traits of such soil, damaging canal slope lining structures. To investigate the mechanical properties of saline clay, this study conducted indoor tests, including direct shear, compression, and permeation tests, and scanning electron microscopy (SEM) analysis of soil samples from typical sites.

View Article and Find Full Text PDF

The anti-inflammatory role of miR-23b-3p (miR-23b) is known in autoimmune diseases like multiple sclerosis, systemic lupus erythematosus, and rheumatoid arthritis. However, its role in sepsis-related acute lung injury (ALI) and its effect on macrophages in ALI remain unexplored. This investigation aimed to evaluate miR-23b's therapeutic potential in macrophages in the context of ALI.

View Article and Find Full Text PDF

Efficacy of SAVE: A Novel Maxillary Protraction Device-A Finite Element Analysis.

Int J Clin Pediatr Dent

December 2024

Department of Orthodontics, Yenepoya Dental College, Yenepoya (Deemed to be University), Mangaluru, Karnataka, India.

Introduction: This study describes a novel device known as "SAVE" to effectively protract the deficient maxilla in class III malocclusion by quantifying and evaluating the changes in the maxilla through a finite element analysis (FEA).

Materials And Methods: The patented novel SAVE device was three-dimensionally modeled using Autodesk Fusion 360. An existing computed tomography (CT) scan of a patient exhibiting class III malocclusion was used to generate a finite element (FE) model.

View Article and Find Full Text PDF

Objective: Primary aim was to analyse dentoalveolar and skeletal effects induced by an anterior open bite (AOB) treatment protocol for intrusion of maxillary buccal segment. Secondary aim was to investigate whether a subsequent change occurred in hyoid position.

Materials And Methods: Study group included 28 non-growing subjects treated in academic setting for correction of AOB.

View Article and Find Full Text PDF

High-affinity VNARs targeting human hemoglobin: Screening, stability and binding analysis.

Int J Biol Macromol

January 2025

College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China. Electronic address:

Hemoglobin, composed of α- and β-chains, is essential for oxygen transport and is key in diagnosing and treating gastrointestinal and blood disorders. It also aids in detecting blood contamination and estimating transfusion volumes. Immunological methods, based on antigen-antibody interactions, are distinguished by their high sensitivity and accuracy.