A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Derivatization-free conventional and synchronous spectrofluorimetric estimation of atenolol and amlodipine. | LitMetric

Derivatization-free conventional and synchronous spectrofluorimetric estimation of atenolol and amlodipine.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt; Department of Chemistry, University of Michigan, Ann Arbor, 48109, MI, United States. Electronic address:

Published: January 2024

Fixed-dose combinations for treatment of hypertension are observed in many dosages in the global market because of their high efficacy compared to single component dosage forms. One of these effective combinations is atenolol/amlodipine which is usually administered to patients with hypertension. Hence, development of facile, accurate, and sensitive methods for simultaneous estimation of atenolol and amlodipine is of great importance for quality control testing and pharmacokinetic studies. In our study, we developed two spectrofluorimetric methods to estimate both compounds in different pharmaceuticals. The first method is based on the estimation of atenolol and amlodipine by double-scan conventional spectrofluorimetry where the fluorescence intensities of atenolol and amlodipine were measured at 299 and 434 nm after excitation at 274 and 358 nm, respectively. The second method depends on synchronous spectrofluorimetric measurements at Δλ = 70 nm, where atenolol is assayed at 266 nm and amlodipine is assayed at 363 nm. Methods' optimizations were carried out to select the optimum conditions that render high selectivity and sensitivity. Such optimizations included assessment of solvents, surfactants, buffer volumes and pHs. The conventional spectrofluorimetric method was rectilinear over concentration range of 30.0-300.0 ng mL for atenolol and 0.25-7.00 µg mL for amlodipine while the synchronous spectrofluorimetric method showed linearity over the ranges of 0.60-6.00 µg mL for atenolol and 0.25-7.00 µg mL for amlodipine with low detection limits (≤0.12 µg mL) for both compounds in the two methods. It is the first work that demonstrates estimation of atenolol and amlodipine in their combinations by conventional and synchronous spectrofluorimetry. Both methods were applied to estimate atenolol and amlodipine in different pharmaceuticals with high %recovery and low %RSD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2023.123532DOI Listing

Publication Analysis

Top Keywords

atenolol amlodipine
24
estimation atenolol
16
synchronous spectrofluorimetric
12
atenolol
9
amlodipine
9
conventional synchronous
8
spectrofluorimetric method
8
atenolol 025-700 µg ml
8
025-700 µg ml amlodipine
8
spectrofluorimetric
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!