Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Current solutions for the analysis of Western Blot images lack either transparency and reproducibility or can be tedious to use if one has to ensure the reproducibility of the analysis.
Results: Here, we present an open-source gel image analysis program, IOCBIO Gel. It is designed to simplify image analysis and link the analysis results with the metadata describing the measurements. The software runs on all major desktop operating systems. It allows one to use it in either a single-researcher environment with local storage of the data or in a multiple-researcher environment using a central database to facilitate data sharing within the research team and beyond. By recording the original image and all operations performed on it, such as image cropping, subtraction of background, sample lane selection, and integration boundaries, the software ensures the reproducibility of the analysis and simplifies making corrections at any stage of the research. The analysis results are available either through direct access to the database used to store it or through the export of the relevant data.
Conclusions: The software is not only limited to Western Blot image analysis and can be used to analyze images obtained as a part of many other widely used biochemical techniques such as isoelectric focusing. By recording the original data and all the analysis steps, the program improves reproducibility in the analysis and contributes to the implementation of FAIR principles in the related fields.