Congenital heart disease (CHD) accounts for nearly one-third of all congenital defects, and patients often require repeated heart valve replacements throughout their lives, due to failed surgical repairs and lack of durability of bioprosthetic valve implants. This objective of this study is to develop and in vitro test a fetal transcatheter pulmonary valve replacement (FTPVR) using sutureless techniques to attach leaflets, as an option to correct congenital defects such as pulmonary atresia with intact ventricular septum (PA/IVS), in utero. A balloon expandable design was analyzed using computational simulations to identify areas of failure. Five manufactured valves were assembled using the unique sutureless approach and tested in the fetal right heart simulator (FRHS) to evaluate hemodynamic characteristics. Computational simulations showed that the commissural loads on the leaflet material were significantly reduced by changing the attachment techniques. Hemodynamic analysis showed an effective orifice area of 0.08 cm, a mean transvalvular pressure gradient of 7.52 mmHg, and a regurgitation fraction of 8.42%, calculated over 100 consecutive cardiac cycles. In conclusion, the FTPVR exhibited good hemodynamic characteristics, and studies with biodegradable stent materials are underway.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-023-03386-9DOI Listing

Publication Analysis

Top Keywords

balloon expandable
8
fetal heart
8
heart valve
8
congenital defects
8
computational simulations
8
hemodynamic characteristics
8
development novel
4
novel sutureless
4
sutureless balloon
4
expandable fetal
4

Similar Publications

Background: Drug-coated balloons (DCB) can decrease the incidence of restenosis in the treatment of intracranial atherosclerotic stenosis (ICAS). This study aimed to assess the safety and efficacy of submaximal angioplasty with DCB dilation compared with aggressive angioplasty in patients with symptomatic ICAS.

Methods: This study prospectively and consecutively enrolled patients with symptomatic ICAS who underwent DCB angioplasty between January 2021 and December 2023.

View Article and Find Full Text PDF

Pancreaticojejunostomy (PJ) is a critical step in pancreaticoduodenectomy (PD), often complicated by the risk of postoperative pancreatic fistula (POPF). This video report demonstrates a novel robotic PJ technique employing a self-expandable metallic stent. The method involves the use of the Da Vinci Xi robotic system and the WallFlex™ Biliary RX Stent for improved anastomotic support, particularly in high-risk cases defined by soft pancreatic texture and narrow duct diameter (<3 mm).

View Article and Find Full Text PDF

Novel Real-Time Fluoroscopic Assessment Method of Transcatheter Heart Valve Expansion Following Balloon-Expandable TAVR.

Circ Cardiovasc Interv

January 2025

Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, Canada. (A.H., J.J., S.O., K.M., J.A.L., P.B., D.A.W., S.L.S., J.G.W., J.S.).

Background: Transcatheter heart valve (THV) underexpansion after transcatheter aortic valve replacement may be associated with worse outcomes. THV expansion can be assessed fluoroscopically using a pigtail for calibration; however, the accuracy of this technique specific to transcatheter aortic valve replacement is unknown. We assessed the accuracy and reproducibility of a novel fluoroscopic method to assess THV expansion using the THV commissural post for calibration.

View Article and Find Full Text PDF

Severe aortic valve stenosis poses a significant risk for the aging population, often escalating from mild symptoms to life-threatening heart failure and sudden death. Without timely intervention, this condition can lead to disastrous outcomes. The advent of transcatheter aortic valve implantation (TAVI) has gained popularity, emerging as an effective alternative for managing severe aortic stenosis (AS) in high-risk patients experiencing deterioration of previously implanted bioprosthetic surgical aortic valves (SAV), which introduces complex challenges such as device compatibility and anatomical considerations.

View Article and Find Full Text PDF

Although the long-term outcomes of the surgical grafts are well defined and reported, the data regarding the mid-and long-term results of the balloon-expandable percutaneous valves in the native right ventricular outflow tract (RVOT) is limited. We retrospectively evaluated 42 patients who underwent PPVI (Sapien® XT valve) to native RVOT due to severe pulmonary regurgitation (PR) and/or moderate to severe pulmonary stenosis (PS) between August 2015 and November 2020. The median patient age at the time of PPVI was 13.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!