A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anchoring fins of fully covered self-expandable metal stents affect pull-out force and stent migration. | LitMetric

Background And Aims: Stent migration and subsequent adverse events are frequently observed in the use of fully covered self-expandable metal stents (FCSEMSs) for distal biliary stenosis. In this study, we identified predictors for stent migration based on biomechanical stent characteristics and associated these findings with clinical outcomes.

Methods: The migration resistance of FCSEMSs was quantified by measuring the pull-out force. We analyzed a single-center retrospective cohort of 178 FCSEMSs for treatment success and adverse events occurring during 180 days of follow-up.

Results: Biomechanical measurements revealed a 4-fold higher migration resistance of FCSEMSs with anchoring fins (AF-FCSEMSs; F = 14.2 ± .1 N) compared with FCSEMSs with flared ends (FE-FCSEMSs; F = 3.8 ± 1.0 N; P < .0001). Clinically, AF-FCSEMSs showed lower rates of migration compared with FE-FCSEMSs (5% vs 34%, P < .0001). Unscheduled ERCP procedures because of stent dysfunction were less frequent in the AF group compared with the FE group (15% vs 29%, P = .046). Cholangitis because of stent dysfunction was observed in 5% of the AF group compared with 19% in the FE group (P = .02). Stent patency rates at 1, 3, and 6 months were higher in the AF group (96%, 90%, and 80%, respectively) compared with the FE group (90%, 74%, and 66%; log-rank test: P = .03).

Conclusions: The pull-out force as a biomechanical stent property predicts the migration resistance of FCSEMSs in distal biliary stenosis and may thus be used to classify stents for this application. AF-FCSEMSs showed a significantly lower rate of migration and adverse events compared with FE-FCSEMSs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2023.10.036DOI Listing

Publication Analysis

Top Keywords

pull-out force
12
stent migration
12
adverse events
12
migration resistance
12
resistance fcsemss
12
fully covered
8
covered self-expandable
8
self-expandable metal
8
metal stents
8
stent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!